Maintenance – Danze D113010BT - Installation Manual User Manual
Page 4
Stub out length for tub
spouts (measured from
finished wall surface)
With Flange: 1/2"
Copper pipe stub-out
length from finished
wall surface
Without Flange: 1/2"
Copper pipe stub-out
length from finished wall
surface
With Flange: 1/2"
Brass/IPS pipe stub-out
length from finished wall
surface
Without Flange: 1/2"
Brass/IPS pipe stub-out
length from finished
wall surface
Largo del tubo de
montaje del grifo
(medido desde la
superficie de la pared
terminada)
Con brida: tubo de
montaje de cobre de
1/2" medido desde la
superficie de la pared
terminada
Sin brida: tubo de montaje
de cobre de 1/2" medido
desde la superficie de la
pared terminada
Con brida: tubo de
montaje de bronce
(IPS) de 1/2" medido
desde la superficie de
la pared terminada
Sin brida: tubo de
montaje de bronce (IPS)
de 1/2 medido desde
la superficie de la
pared terminada
Longueur du tuyau qui
dépasse pour les becs
de baignoire (mesurée
à partir de la surface
du mur fini)
Avec bride : Longueur
du tuyau de cuivre de
1/2 po (1,3 cm) qui
dépasse de la surface
du mur fini
Sans bride : Longueur du
tuyau de cuivre de 1/2"
po (1,3 cm) qui dépasse
de la surface du mur fini
Avec bride : Longueur
du tuyau de laiton/IPS
de 1/2 po (1,3 cm)
qui dépasse de la
surface du mur fini
Sans bride : Longueur
du tuyau de laiton/IPS
de 1/2 po (1,3 cm)
qui dépasse de la
surface du mur fini
Sonora, Parma, Opulence,
Brandywood, South Sea
1-3/8" to 2-1/2"
na
1-5/8" to 1-3/4"
na
Sonora, Parma,
Opulence,Brandywood
South Sea
1-3/8" a 2-1/2"
n/a
1-5/8" a 1-3/4"
n/a
Sonora, Parma,
Opulence,
Brandywood, South Sea
1-3/8 à 2-1/2 po
(3,5 à 6,4 cm)
SO
1-5/8 à 1-3/4 po
(4,1 à 4,5 cm)
SO
Bannockburn,
Sheridan, Plymouth,
Melrose, Antioch
Sirius
1-1/2" to 2"
na
1-3/8" to 1-7/8"
1-1/8" to 1-5/8"
1-7/8"
na
2"
1-1/2" to 1-5/8"
Corsair
1/2" copper pipe stub-out
1/2" brass/IPS pipe stub-out
na
1-1/2" to 2"
na
1-7/8"
Corsair
n/a
1-1/2" to 2"
n/a
1-7/8"
Corsair
1-1/2" à 2"
1-7/8"
Sirius
n/a
1-1/8" to 1-5/8"
n/a
1-1/2" to 1-5/8"
Sirius
SO
1-1/8" à 1-5/8"
SO
SO
SO
1-1/2" à 1-5/8"
Bannockburn,
Sheridan, Plymouth,
Melrose, Antioch
1-1/2" a 2"
1-3/8" a 1-7/8"
1-7/8"
2"
Bannockburn,
Sheridan, Plymouth,
Melrose, Antioch
1-1/2 à 2 po
(3,8 à 5,1 cm)
1-3/8 à 1-7/8 po
(3,5 à 4,8 cm)
1-7/8 po (4,8 cm)
2 po (5,1 cm)
1/2"-14NPT
Maintenance
Your new faucet is designed for years of trouble-free performance. Keep it looking new by cleaning it periodically
with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as these will dull the finish and void your warranty.
O.D= ø 5/8"
2.3.2
FINISHED WALL
2.3.1
ATTENTION:
Pour s’assurer que le tout fonctionne correctement, la tuyauterie
reliant l’orifice inférieur du robinet à la sortie du bec du bain DOIT consister
soit en un tuyau de cuivre de 1/2 po nominal ou en un tuyau IPS de 1/2 po.
2.3.1 Install shower piping to top port of valve.
Install tub filler piping to bottom port of valve.
Instale la tubería para la ducha en la entrada superior de la válvula.
Instale la tubería para la bañera en la entrada inferior.
Raccorder la tuyauterie de douche à l’orifice supérieur du robinet.
Raccorder la tuyauterie du bec déverseur de baignoire à l’orifice inférieur du
robinet.
2.3.2 Stub-out pipe for spout installation must be at the length illustrated
measured from the finished wall surface.
El tubo de montaje para la instalación del grifo debe sobresalir como se
muestra en la ilustración, midiendo desde la superficie de la pared terminada.
Le tuyau qui dépasse pour l'installation du bec doit être de la longueur
illustrée, en le mesurant à partir de la surface du mur fini.
4