Danze D423058 - Homeowner Manual User Manual
Page 6

®
5
Hands Free Operation Trouble Shooting Guide
There is no object within the detection range but the red light is continuously on.
• After first turning the unit on it will go into programming mode automatically for a few seconds. The light will turn off automatically
after a few seconds.
• The unit is sensing a stationary object in front of the lens. This object may not be obvious to the user. The unit will reprogram itself
and the light will turn off after a few seconds.
• If the light stays on indefinitely, the electronic module may be faulty
4.
The solenoid valve appears to be functioning incorrectly
• Check all water connections
• Check solenoid valve electronic connections
• When placing a hand in front of the sensor, check whether there is an audible “click” from the solenoid valve
• Check the filter on the solenoid valve and clean as necessary
• Change the solenoid valve
5.
The water flow is too low
• Check to make sure that the hot/cold inlet valves are fully open
• Check the filter on the solenoid valve and clean as necessary
• Check the spout nozzle and clean as necessary
6.
The mixed water does not have the desired temperature
• Turn the handle on the water mixer to change temperature – more towards the red or blue range if the mixed water temperature is
too cold or too hot.
• Check hot and cold water hoses for proper connection
7.
Hands free activated water run time
• See installation instructions
8.
© 2009 Danze, Inc. All rights reserved.