USER PIN ENTRY MODE – Auto or Manual (Location 70)

USER PIN ENTRY MODES
Two modes 1 and 2 are available for User PIN entry options. The EM Card is always in Auto Entry
Mode
and is not affected by the selection here.

1

--- Auto Entry Mode

Auto Entry Mode requires no pressing of the

#

key following the User PIN for code checking.

In the Auto Entry Mode, the User PINs MUST be set in the same digit length of the Master Code

(For example, if the Master Code is 5 digits, then all User PINs must be in 5 digits as well. All other

User PINs not in 5 digits become invalid). When the number of digits reaches, the system will check

the User PIN automatically. Good for high traffic access control.

2

--- Manual Entry Mode – (Default)

Manual Entry Mode always requires the

#

key following of the User PIN for code checking. The

User PINs can be 4-8 digits arbitrary and they are NOT required to be in the same digit length of
the Master Code. Manual Entry increases the level of security in the code trial by the unauthorized

people.

PACIFIER TONES ON-OFF SELECTION (Location 71)

PACIFIER TONES ON-OFF MODES
The Pacifier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry (1
beep), the Output Operation Announcer (2 beeps or 1 long beep) and the Unsuccessful User Code/
Card entry (5 beeps).
NOTE :
The beeps for the Warning and the Power-up Delay do not belong to pacifier tones and can not be set

to OFF.

1

--- Pacifier Tone ON – (Default)

All the Pacifier Tones available from the keypad are enabled. They are the response tones indicating
the operation status of the keypad after the Card/User Code is entered.

0

--- Pacifier Tone OFF

All the Pacifier Tones are OFF. Good for place needs for a silent environment.

OUTPUT OPERATION ANNOUNCER (Location 72)

OUTPUT OPERATION ANNOUNCER
The announcer gives notification beep to the users and the visitors on the operation status of the

outputs. There are two notification modes available for the selection.The notification is also OFF while
the Pacifier Tone OFF mode in the Location 71 is selected.

1

--- 1 Second Long Notification -- (Default)

1 second notification beep is given when the output relay is activated with a valid Card/Code or

Egress Button. It is prepared to notify the person outside the door when the lock is released and

the door can be opened. It is good for the door lock device gives no sound when it activates, such

as a magnetic lock.

0

--- 2 Short Beeps Notification

2 short beeps notification is given when the output is activated with a valid Card/Code.

ENTRY MODES

VALIDATION

LOCATION

1

or

2

70

#

FUNCTION MODES VALIDATION

LOCATION

FUNCTION MODES VALIDATION

LOCATION

1

or

0

1

or

0

#

#

71

72

24