Operation : (while the system is in the operation mode)
#
(a) (b) (c)
(a)
(b)
(c)
NOTE: The Duress Event can not be reported if the operation mode is EM Card alone. It is required
to key in the Duress Code directly if necessary.
VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40)
The Visitor Codes are the temporary user codes for operating of the Output 1 (mainly for door strike
in access control). They can be programmed as “One Time Codes” or “Codes with Time Limit”. The
Visitor Codes will be cleared automatically after use if they are one time codes, or, when the allowed
time expires.
VISITOR ID
50 Visitor IDs for storing the codes. They are represented by a
Two-digit ID Number of
01
to
50
.
0999
= Clear all the Visitor Codes from Location 40. Please
see the Programming example below for the details.
VALID PERIOD
The codes in this box MUST be two digits and they represent the time of the operation.
00
--- One Time Code
One Time Code has no time limit but it can only be used for ONCE.
It is cleared by the system automatically after use.
01
-
99
--- Time Limit in Hour(s)
The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a
two-digit number of 01 to 99. The visitor code is cleared by the system when
the time limit reaches.
VISITOR CODES
When a new Visitor Code is put in the same Code box, the old code is replaced.
The Visitor Codes can be 4-8 digits for the Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code
entry.
The Visitor Codes can not reset Duress Output.
NOTE: All Vistor Codes will be cleared after power down to prevent extension/confusion of
their valid time limit.
EXAMPLES:
Example 1: Set a “One Time Visitor Code” with the number of “1 2 6 8” for the Output 1
40
01
00
1268
#
(a) (b) (c) (d) (e)
(a) Visitor Code Programming, (b) The Visitor ID, (c) An One Time Code, (d) The Visitor Code,
(e) Entry Confirmation
Example 2: Set a “Visitor Code” with the number of “1 3 7 8” that is valid for three hours for the
Output
1
40
02
03
1378
#
(a) (b) (c) (d) (e)
(a) Visitor Code Programming, (b) The Visitor ID, (c) Valid for 3 Hours, (d) The Visitor Code, (e)
Entry Confirmation
Read Card
Duress Code
4-8 DIGITS
40
#
01
-
50 00
or
01
-
99
VISITOR CODE VALIDATION
LOCATION
VISITOR ID
VALID PERIOD
20
Put the EM card close to the reader. One-beep confirms the reading and 30 seconds waiting
time is given for the entry of the Duress Code, the Amber LED keeps flashing
Key in one of the Duress Codes for the specific output (the Code programmed in “Location 41,
42, or 43” for Output 1, 2 and 3 respectively)
Confirm it with the # key. The specific Output activates in a normal way and the Duress Output
also activates to report Duress Event to an alarm system.