12m net power – Milton CAT 12M User Manual
Page 19

19
12M Motor Grader specifications
Std – Fan speed – max
1,450 rpm
Std – Fan speed
– min
600 rpm
Std – Ambient Capability
43° C
109° F
Hi Ambient – Fan speed – max
1,650 rpm
Hi Ambient – Fan speed
– min
600 rpm
Hi Ambient Capability
50° C
122° F
• Max torque (VHP Plus) measured at 1,400 rpm.
• Net power is tested per ISO 9249, SAE J1349, and EEC 80/1269
Standards in effect at the time of manufacture.
• VHP Plus is an optional attachment.
• Net power advertised is the power available at rated speed
of 2,000 rpm, measured at the flywheel when engine is
equipped with fan running at minimum speed, air cleaner,
muffler and alternator.
• No engine derating required up to 3505 m (11,500 ft).
Engine
Engine Model
Cat
®
C6.6 ACERT™ VHP
Base Power (1st gear) – Net
118 kW
158 hp
VHP range – Net
118-129 kW
158-173 hp
VHP Plus range – Net
118-144 kW
158-193 hp
Displacement
6.6 L
403 in
3
Bore
105 mm
4.13 in
Stroke
125 mm
4.92 in
Torque Rise (VHP Plus)
40%
Max Torque (VHP Plus)
963 N·m
710 lb ft
Speed @ rated power
2,000 rpm
Number of cylinders
6
Derating altitude
3505 m
11,500 ft
12M Net Power
VHP
VHP Plus
Gear
kW (hp) – Net
kW (hp) – Net
Fwd. 1st
118 (158)
118 (158)
2nd
121 (163)
121 (163)
3rd
125 (168)
125 (168)
4th
129 (173)
129 (173)
5th
129 (173)
132 (178)
6th
129 (173)
136 (183)
7th
129 (173)
139 (188)
8th
129 (173)
144 (193)
Rev. 1st
118 (158)
118 (158)
2nd
121 (163)
121 (163)
3rd – 6th
125 (168)
125 (168)
Power Train
Forward/Reverse Gears
8 Fwd/6 Rev
Transmission
Direct drive, power
shift, countershaft
Brakes – Service
Multiple oil-disc
Brakes
– Service, surface area
23 000 cm
2
3,565 in
2
Brakes
– Parking
Multiple oil disc
Brakes
– Secondary
Dual circuit control system
Hydraulic System
Circuit type
Electro-hydraulic
closed center, load sensing
Pump type
Variable piston
Pump output
193 L/min
51 gal/min
Maximum system pressure
24 100 kPa
3,500 psi
Standby Pressure
3100 kPa
450 psi
• Pump output measured at 2,150 rpm