Fig. 6 - Current Ratings Characteristics
Fig. 7 - Forward Voltage Drop Characteristics
Fig. 8 Total Power Loss Characteristics
Fig. 9 - Maximum Non-Repetitive Surge Current
Fig. 10 - Maximum Non-Repetitive Surge Current
0
40
Maxim
u
m Allo
wab
le
Case T
e
mperature
(°C)
Total Output Current (A)
5
10
15
25
50
70
90
110
130
150
36MT.. Series
120° (rect.)
35
20
30
~
+
-
1
1.0
1.5
2.0
2.5
3.0
3.5
4.0
10
1000
Instantaneous Forward Current (A)
Instantaneous Forward Voltage (V)
36MT.. Series
T
J
= 25 °C
T
J
= 150 °C
Per junction
100
0
0.5
0
5
15
25
35
Total Output Current (A)
Maximum Total Power Loss (W)
0
10
20
40
60
80
70
50
30
120° (rect.)
10
20
30
36MT.. Series
T
J
= 150 °C
0
25
50
100
150
Maximum Allowable Ambient Temperature (°C)
Maximum Total Power Loss (W)
0
10
20
30
50
80
70
60
40
1 K/
W
75
125
10 K/W
7 K/W
5 K/W
4 K/
W
3 K/
W
2 K/
W
R
thSA
= 0.7 K/
W
- Δ
R
1
10
100
Number of Equal Amplitude Half Cycle
Current Pulses (N)
Peak Half Sine Wave
Forward Current (A)
100
200
300
400
450
At any rated load condition and with
rated V
RRM
applied following surge.
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
Initial T
J
= 150 °C
36MT.. Series
350
250
150
0.01
0.1
1
Pulse Drain Duration (s)
Peak Half Sine Wave
Forward Current (A)
100
150
200
250
300
400
450
500
Maximum non repetitive surge current
versus pulse train duration.
No voltage reapplied
Rated V
RRM
reapplied
Initial T
J
= 150 °C
36MT.. Series
350