beautypg.com

400u(r) series, Vishay high power products, Standard recovery diodes (stud version), 400 a – C&H Technology 400U(R) Series User Manual

Page 3

background image

www.vishay.com

For technical questions, contact: [email protected]

Document Number: 93510

2

Revision: 23-Jun-08

400U(R) Series

Vishay High Power Products

Standard Recovery Diodes

(Stud Version), 400 A

Note
• The table above shows the increment of thermal resistance R

thJC

when devices operate at different conduction angles than DC

FORWARD CONDUCTION

PARAMETER

SYMBOL

TEST CONDITIONS

VALUES

UNITS

Maximum average forward current
at case temperature

I

F(AV)

180° conduction, half sine wave

400

A

120

°C

Maximum RMS forward current

I

F(RMS)

DC at 110 °C case temperature

630

A

Maximum peak, one cycle forward,
non-repetitive surge current

I

FSM

t = 10 ms

No voltage
reapplied

Sinusoidal half wave,
initial T

J

= T

J

maximum

8250

A

t = 8.3 ms

8640

t = 10 ms

100 % V

RRM

reapplied

6940

t = 8.3 ms

7270

Maximum I

2

t for fusing

I

2

t

t = 10 ms

No voltage
reapplied

340

kA

2

s

t = 8.3 ms

311

t = 10 ms

100 % V

RRM

reapplied

241

t = 8.3 ms

220

Maximum I

2

√t for fusing

I

2

√t

t = 0.1 to 10 ms, no voltage reapplied

3400

kA

2

√s

Low level value of threshold voltage

V

F(TO)1

(16.7 % x

π x I

F(AV)

< I <

π x I

F(AV)

), T

J

= T

J

maximum

0.77

V

High level value of threshold voltage

V

F(TO)2

(I >

π x I

F(AV)

), T

J

= T

J

maximum

0.85

Low level value of forward
slope resistance

r

f1

(16.7 % x

π x I

F(AV)

< I <

π x I

F(AV)

), T

J

= T

J

maximum

0.49

m

Ω

High level value of forward
slope resistance

r

f2

(I >

π x I

F(AV)

), T

J

= T

J

maximum

0.49

Maximum forward voltage drop

V

FM

I

pk

= 1500 A, T

J

= T

J

maximum, t

p

= 10 ms sinusoidal wave

1.62

V

THERMAL AND MECHANICAL SPECIFICATIONS

PARAMETER

SYMBOL

TEST CONDITIONS

VALUES

UNITS

Maximum junction operating and
storage temperature range

T

J

, T

Stg

- 40 to 200

°C

Maximum thermal resistance,
junction to case

R

thJC

DC operation

0.15

K/W

Maximum thermal resistance,
case to heatsink

R

thCS

Mounting surface, smooth, flat and greased

0.04

Maximum allowed mounting torque
± 10 %

Not lubricated threads

27

N · m

Approximate weight

250

g

Case style

See dimensions - link at the end of datasheet

DO-205AB (DO-9)

ΔR

thJC

CONDUCTION

CONDUCTION ANGLE

SINUSOIDAL CONDUCTION

RECTANGULAR CONDUCTION

TEST CONDITIONS

UNITS

180°

0.020

0.013

T

J

= T

J

maximum

K/W

120°

0.023

0.023

90°

0.029

0.031

60°

0.042

0.044

30°

0.073

0.074