Vishay high power products, Schottky rectifier, 300 a – C&H Technology 300CNQ045PbF User Manual
Page 5
www.vishay.com
For technical questions, contact: [email protected]
Document Number: 94175
4
Revision: 28-Apr-08
300CNQ045PbF
Vishay High Power Products
Schottky Rectifier, 300 A
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
Fig. 7 - Maximum Non-Repetitive Surge Current (Per Leg)
Fig. 8 - Unclamped Inductive Test Circuit
Note
(1)
Formula used: T
C
= T
J
- (Pd + Pd
REV
) x R
thJC
;
Pd = Forward power loss = I
F(AV)
x V
FM
at (I
F(AV)
/D) (see fig. 6);
Pd
REV
= Inverse power loss = V
R1
x I
R
(1 - D); I
R
at V
R1
= 80 % rated V
R
I
F(AV)
- Average Forward Current (A)
Allowable Case Temperature (°C)
0
50
100
150
200
250
60
80
100
120
140
160
DC
Square wave (D = 0.50)
80 % rated V
R
applied
See note (1)
I
F(AV)
- Average Forward Current (A)
Average Power Loss (W)
0
20
40
60
80
100
120
140
DC
RMS limit
0
50
100
150
200
250
D = 0.75
D = 0.50
D = 0.33
D = 0.25
D = 0.20
t
p
- Square Wave Pulse Duration (µs)
I
FSM
- Non-Repetitive Surge Current (A)
1000
10 000
100 000
At any rated load condition
and with rated V
RRM
applied
following surge
10
100
1000
10 000
Current
monitor
High-speed
switch
D.U.T.
R
g
= 25
Ω
+
Freewheel
diode
V
d
= 25 V
L
IRFP460
40HFL40S02