40eps16 safe, Series – C&H Technology 40EPS16 SAFEIR Series User Manual
Page 4

40EPS16 SAFE
IR
Series
Bulletin I2160 10/01
Fig. 1 - Current Rating Characteristics
Fig. 2 - Current Rating Characteristics
Fig. 4 - Forward Power Loss Characteristics
Fig. 3 - Forward Power Loss Characteristics
Fig. 6 - Maximum Non-Repetitive Surge Current
Fig. 5 - Forward Voltage Drop Characteristics
Instantaneous Forward Voltage (V)
Instantaneous Forward Current (A)
Maximum Allowable Case Temperature (°C)
Average Forward Curren t (A)
95
100
105
110
115
120
125
130
135
140
145
150
0
5
10 15 20 25 30 35 40 45
30˚
60˚
90˚
120˚
180˚
Conduction Angle
40EPS16
RthJC (DC) = 0.6 K/W
Maximum Allowable Case Temperature (°C)
Average Forward Curren t (A)
Maximum Average Forward Power Loss (W)
Average Forward Curren t (A)
Maximum Average Forward Power Loss (W)
Average Forward Curren t (A)
Pulse Train Duration (s)
Peak Half Sine Wave Forward Current (A)
100
110
120
130
140
150
0
10
20
30
40
50
60
70
DC
30˚
60˚
90˚
120˚
180˚
Conduction Period
40EPS16
RthJC (DC) = 0.6 K/W
0
5
10
15
20
25
30
35
40
45
50
55
60
0
5
10
15
20
25
30
35
40
RMS Limit
Conduction Angle
180˚
120˚
90˚
60˚
30˚
40EPS16
Tj = 150˚C
0
10
20
30
40
50
60
70
80
0
10
20
30
40
50
60
70
DC
180˚
120˚
90˚
60˚
30˚
RMS Limit
Conduction Period
40EPS16
Tj = 150˚C
1
10
100
1000
0.5
1.5
2.5
Tj = 25˚C
Tj = 150˚C
40EPS16
100
150
200
250
300
350
400
450
500
0.01
0.1
1
Maximum Non Repetitive Surge Current
40EPS16
Initial Tj = 150 ˚C
No Voltage Reapplied
Rated Vrrm Reapplied
Versus Pulse Train Duration.
Document Number: 93512
www.vishay.com
3