beautypg.com

S-12 – C&H Technology CM4308A2 User Manual

Page 5

background image

S-12

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

CM4308A2
Dual SCR POW-R-BLOK™ Modules
25 Amperes/800 Volts

MAXIMUM ON-STATE POWER DISSIPATION

(REVERSE PARALLEL CONNECTION)

RMS ON-STATE CURRENT, I

(RMS)

, (AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

10

50

20

30

40

60

70

80

0

360

o

RESISTIVE,

INDUCTIVE LOAD

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE AVERAGE ON-STATE POWER DISSIPATION PER MODULE

AND THE RMS ON-STATE CURRENT.

10

20

30

40

50

60

70

80

90

o

60

o

30

o

120

o

= 180

o

MAXIMUM ALLOWABLE CASE TEMPERATURE

(SINGLE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

C

, (AMPERES)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

10

50

20

30

40

80

90

100

110

120

130

= 30

o

60

o

90

o

360

o

RESISTIVE,

INDUCTIVE

LOAD

5

15

25

35

45

125

115

105

95

85

180

o

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE CASE TEMPERATURE AND THE DC OUTPUT CURRENT

(FOR TWO ELEMENTS) WHEN USED IN THE SINGLE PHASE

BRIDGE CONFIGURATION.

120

o

MAXIMUM ON-STATE POWER DISSIPATION

(SINGLE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

O

, (AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

5

0

360

o

RESISTIVE,

INDUCTIVE LOAD

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE AVERAGE ON-STATE POWER DISSIPATION AND THE DC

OUTPUT CURRENT FOR THE SINGLE PHASE BRIDGE

CONFIGURATION (POWER DISSIPATION EXPRESSED FOR EACH

MODULE AND DC OUTPUT CURRENT EXPRESSED FOR THE PAIR)

10

20

30

40

50

60

70

80

10 15 20 25 30 35 40 45 50

= 30

o

120

o

90

o

60

o

180

o

MAXIMUM ON-STATE POWER DISSIPATION

(THREE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

O

, (AMPERES)

MAXIMUM POWER DISSIPATION, P

AV(MAX)

, (WATTS)

0

10

50

20

30

40

60

70

80

0

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE ON-STATE POWER DISSIPATION (PER MODULE) AND THE

DC OUTPUT CURRENT (FOR THREE MODULES) IN THE THREE

PHASE BRIDGE CONFIGURATION.

10

20

30

40

50

60

70

80

360

o

RESISTIVE, INDUCTIVE LOAD

PER SINGLE ELEMENT

= 30

o

120

o

90

o

60

o

80

MAXIMUM ALLOWABLE CASE TEMPERATURE

(THREE PHASE BRIDGE CONNECTION)

DC OUTPUT CURRENT, I

O

, (AMPERES)

MAXIMUM ALLOWABLE CASE TEMPERATURE, T

C

, (

o

C)

0

10

50

20

30

40

60

70

80

85

95

110

115

120

125

130

360

o

NOTE: THE CURVES INDICATE THE RELATIONSHIP BETWEEN

THE CASE TEMPERATURE AND THE DC OUTPUT CURRENT

(FOR THREE MODULES) IN THE THREE PHASE CONFIGURATION.

RESISTIVE,

INDUCTIVE

LOAD

= 30

o

60

o

90

o

120

o

105

100

90