Cd42 c cd47 c, Pow-r-blok, Electrical characteristics, t – C&H Technology CD47__90C User Manual
Page 4: 25°c unless otherwise specified, Thermal characteristics

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
POW-R-BLOK
TM
http://www.pwrx.com
Dual SCR/Diode Isolated Module
90 Amperes / Up to 1800 Volts
Revision Date: 08/31/2011
CD42__90C
CD47__90C
Electrical Characteristics, T
J
=25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Max.
Units
Repetitive Peak Forward Leakage Current
I
DRM
Up to V
DRM
, T
J
=125°C
10
mA
Repetitive Peak Reverse Leakage Current
I
RRM
Up to V
RRM
, T
J
=125°C
10
mA
Peak On-State Voltage
V
TM
I
TM
=270A
1.70
V
Threshold Voltage, Low-level
Slope Resistance, Low-level
V
(TO)1
r
T1
T
J
= 125°C, I = 16.7% x
I
T(AV)
to
I
T(AV)
0.8
3.01
V
m
Ω
Minimum dV/dt
dV/dt
T
j
=125°C, V
DM
= 0.67 V
DRM
800
V/µs
Gate Trigger Current
I
GT
T
j
= 25°C, V
D
=12V, I
A
= 1 A
30
100
mA
Gate Trigger Voltage
V
GT
T
j
= 25°C, V
D
=12V, I
A
= 1 A
1.0
2.5
Volts
Holding Current
I
H
T
j
= 25°C, V
D
=12V, I
A
= 1 A
20
100
mA
Thermal Characteristics
Characteristics
Symbol
Max.
Units
Thermal Resistance, Junction to Case
DC Operation
R
ΘJ-C
Per Junction, both conducting
0.28
°C/W
Thermal Resistance, Case to Sink Lubricated
R
ΘC-S
Per Module
0.15
°C/W