C&H Technology PM200CLA060 User Manual
Page 4
3
PM200CLA060
Intellimod™ L-Series
Three Phase IGBT Inverter
200 Amperes/600 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector-Emitter Cutoff Current
I
CES
V
CE
= V
CES
, V
D
= 15V, T
j
= 25°C
—
—
1.0
mA
V
CE
= V
CES
, V
D
= 15V, T
j
= 125°C
—
—
10
mA
Diode Forward Voltage
V
EC
-I
C
= 200A, V
CIN
= 15V, V
D
= 15V
—
2.2
3.3
Volts
Collector-Emitter Saturation Voltage
V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 200A,
—
1.6
2.1
Volts
T
j
= 25°C
V
D
= 15V, V
CIN
= 0V, I
C
= 200A,
—
1.5
2.0
Volts
T
j
= 125°C
Inductive Load Switching Times
t
on
0.5
1.0
2.4
µs
t
rr
V
D
= 15V, V
CIN
= 0 ⇔ 15V
—
0.2
0.4
µs
t
C(on)
V
CC
= 300V, I
C
= 200A
—
0.4
1.0
µs
t
off
T
j
= 125°C
—
1.2
2.5
µs
t
C(off)
—
0.5
1.0
µs
Control Sector
Short Circuit Trip Level
SC
-20°C ≤ T
j
≤ 125°C, V
D
= 15V
400
—
—
Amperes
Short Circuit Current Delay Time
t
off(SC)
V
D
= 15V
—
0.2
—
µs
Over Temperature Protection
OT
Trip Level
135
145
155
°C
(Detect T
j
of IGBT Chip)
OT
R
Reset Level
—
125
—
°C
Supply Circuit Under-voltage Protection
UV
Trip Level
11.5
12.0
12.5
Volts
(-20 ≤ T
j
≤ 125°C)
UV
R
Reset Level
—
12.5
—
Volts
Circuit Current
I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
—
18
28
mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
—
6
12
mA
Input ON Threshold Voltage
V
th(on)
Applied between U
P
-V
UPC
,
1.2
1.5
1.8
Volts
Input OFF Threshold Voltage
V
th(off)
V
P
-V
VPC
, W
P
-V
WPC
, U
N
- V
N
- W
N
-V
NC
1.7
2.0
2.3
Volts
Fault Output Current*
I
FO(H)
V
D
= 15V, V
CIN
= 15V
—
—
0.01
mA
I
FO(L)
V
D
= 15V, V
CIN
= 15V
—
10
15
mA
Fault Output Pulse Width*
t
FO
V
D
= 15V
1.0
1.8
—
ms
*Fault output is given only when the internal SC, OT and UV protections schemes of either upper or lower devide operate to protect it.