C&H Technology PS21265-AP User Manual
Page 5

4
PS21265-P / PS21265-AP
Intellimod™ Module
Dual-In-Line Intelligent Power Module
20 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
08/10 Rev. 01
Electrical and Mechanical Characteristics,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Circuit Current
I
D
V
D
= V
DB
= 15V, V
IN
= 5V,
—
—
7.00
mA
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= V
DB
= 15V, V
IN
= 0V,
—
—
7.00
mA
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= V
DB
= 15V, V
IN
= 5V,
—
—
0.55
mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
V
D
= V
DB
= 15V, V
IN
= 0V,
—
—
0.55
mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
Fault Output Voltage
V
FOH
V
SC
= 0V, F
O
Circuit: 10kΩ to 5V Pull-up
4.9
—
—
Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA
—
—
0.95
Volts
Input Current
I
IN
V
IN
= 5V
1.0
1.5
2.00
mA
Short-Circuit Trip Level*
V
SC(ref)
T
C
= 20 ~ 100°C, V
D
= 15V
0.45
—
0.52
Volts
Supply Circuit Undervoltage
UV
DBt
Trip Level, T
j
≤ 125°C
10.0
—
12.0
Volts
Protection
UV
DBr
Reset Level, T
j
≤ 125°C
10.5
—
12.5
Volts
UV
Dt
Trip Level, T
j
≤ 125°C
10.3
—
12.5
Volts
UV
Dr
Reset Level, T
j
≤ 125°C
10.8
—
13.0
Volts
Fault Output Pulse Width**
t
FO
C
FO
= 22nF
1.0
1.8
—
ms
ON Threshold Voltage
V
th(on)
Applied between U
P
, V
P
, W
P
-V
PC,
2.1
2.3
2.6
Volts
OFF Threshold Voltage
V
th(off)
U
N
, V
N
, W
N
-V
NC
0.8
1.4
2.1
Volts
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Fin
R
th(j-f)Q
IGBT Part (Per 1/6 Module)
—
—
1.95
°C/W
Thermal Resistance
R
th(j-f)D
FWDi Part (Per 1/6 Module)
—
—
3.00
°C/W
Contact Thermal Resistancw
R
th(c-f)
Case to Fin (Per 1 Module)
—
—
0.067
°C/W
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 30A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width t
FO
depends on the capacitance value
of C
FO
according to the following approximate equation: C
FO
= (12.2 x 10
-6
) x t
FO
{F} .