St180spbf series, Vishay high power products, Phase control thyristors (stud version), 200 a – C&H Technology ST180SPbF Series User Manual
Page 3: On-state conduction, Switching, Blocking
![background image](/manuals/267004/3/background.png)
www.vishay.com
For technical questions, contact: [email protected]
Document Number: 94397
2
Revision: 30-Apr-08
ST180SPbF Series
Vishay High Power Products
Phase Control Thyristors
(Stud Version), 200 A
ON-STATE CONDUCTION
PARAMETER SYMBOL
TEST
CONDITIONS
VALUES
UNITS
Maximum average on-state current
at case temperature
I
T(AV)
180° conduction, half sine wave
200
A
85
°C
Maximum RMS on-state current
I
T(RMS)
DC at 76 °C case temperature
314
A
Maximum peak, one-cycle
non-repetitive surge current
I
TSM
t = 10 ms
No voltage
reapplied
Sinusoidal half wave,
initial T
J
= T
J
maximum
5000
t = 8.3 ms
5230
t = 10 ms
100 % V
RRM
reapplied
4200
t = 8.3 ms
4400
Maximum I
2
t for fusing
I
2
t
t = 10 ms
No voltage
reapplied
125
kA
2
s
t = 8.3 ms
114
t = 10 ms
100 % V
RRM
reapplied
88
t = 8.3 ms
81
Maximum I
2
√t for fusing
I
2
√t
t = 0.1 to 10 ms, no voltage reapplied
1250
kA
2
√s
Low level value of threshold voltage
V
T(TO)1
(16.7 % x
π x I
T(AV)
< I <
π x I
T(AV)
), T
J
= T
J
maximum
1.08
V
High level value of threshold voltage
V
T(TO)2
(I >
π x I
T(AV)
), T
J
= T
J
maximum
1.14
Low level value of on-state slope resistance
r
t1
(16.7 % x
π x I
T(AV)
< I <
π x I
T(AV)
), T
J
= T
J
maximum
1.18
m
Ω
High level value of on-state slope resistance
r
t2
(I >
π x I
T(AV)
), T
J
= T
J
maximum
1.14
Maximum on-state voltage
V
TM
I
pk
= 570 A, T
J
= 125 °C, t
p
= 10 ms sine pulse
1.75
V
Maximum holding current
I
H
T
J
= T
J
maximum, anode supply 12 V resistive load
600
mA
Maximum (typical) latching current
I
L
1000 (300)
SWITCHING
PARAMETER SYMBOL
TEST
CONDITIONS
VALUES
UNITS
Maximum non-repetitive rate of rise
of turned-on current
dI/dt
Gate drive 20 V, 20
Ω, t
r
≤ 1 µs
T
J
= T
J
maximum, anode voltage
≤ 80 % V
DRM
1000
A/µs
Typical delay time
t
d
Gate current 1 A, dI
g
/dt = 1 A/µs
V
d
= 0.67 % V
DRM
, T
J
= 25 °C
1.0
µs
Typical turn-off time
t
q
I
TM
= 300 A, T
J
= T
J
maximum, dI/dt = 20 A/µs,
V
R
= 50 V, dV/dt = 20 V/µs, gate 0 V 100
Ω, t
p
= 500 µs
100
BLOCKING
PARAMETER SYMBOL
TEST
CONDITIONS
VALUES
UNITS
Maximum critical rate of rise
of off-state voltage
dV/dt
T
J
= T
J
maximum linear to 80 % rated V
DRM
500
V/µs
Maximum peak reverse and
off-state leakage current
I
RRM
,
I
DRM
T
J
= T
J
maximum, rated V
DRM
/V
RRM
applied
30
mA