C&H Technology PS22A72 User Manual
Page 5

PS22A72
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/1200 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
4
Rev. 08/09
Thermal Characteristics, T
j
= 25°C unless otherwise specified
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Thermal Resistance Junction to Case R
th(j-C)Q
IGBT Part (Per 1/6 Module)
—
—
2.24
°C/Watt
Thermal Resistance Junction to Case R
th(j-C)D
FWDi Part (Per 1/6 Module)
—
—
2.74 °C/Watt
Recommended Conditions for Use
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Supply Voltage
V
CC
Applied between P-NU, NV, NW
350
600
800
Volts
Control Supply Voltage
V
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
13.5
15.0
16.5
Volts
V
DB
Applied between V
UFB
-V
UFS
,
13.0
15.0
18.5
Volts
V
VFB
-V
VFS
, V
WFB
-V
WFS
Control Supply Variation
ΔV
D
, ΔV
DB
-1
—
1
V/µs
Arm Shoot-through
t
DEAD
For Each Input Signal, T
C
≤ 100°C
3.3
—
—
µs
Blocking Time
PWM Input Frequency
f
PWM
T
C
≤
100°C, T
j
≤ 125°C
—
—
15
kHz
Allowable rms Current*
I
O
V
CC
= 600V, V
D
= 15V,
—
—
1.8
Arms
f
C
= 15kHz, PF = 0.8, Sinusoidal PWM,
T
j
≤ 125°C, T
C
≤ 100°C
Minimum Input
P
WIN(on)
**
—
—
—
µs
Pulse Width
P
WIN(off)***
I
C
≤ 5A
350 ≤ V
CC
≤ 800V, 13.5 ≤ V
D
≤ 16.5V,
—
—
—
µs
5 ≤ I
C
≤
8.5A
13.5 ≤ V
DB
≤ 16.5V, -20°C ≤ T
C
≤ 100°C,
—
—
—
µs
N-line Wiring Inductance Less Than 10nH
V
NC
Variation
V
NC
Between V
NC
-NU, NV, NW (Including Surge)
-5.0
—
5.0
Volts
* The allowable rms current value depends on the actual application conditions.
**If input signal ON pulse is less than PWIN(on), the device may not respond.
***The IPM may fail to respond to an ON pulse if the preceeding OFF pulse is less than PWIN(off).
Delayed Response Against Shorter Input OFF Signal Than PWIN
(off)
, P-side only
t2
t1
P-SIDE
CONTROL INPUT
INTERNAL
IGBT GATE
OUTPUT
CURRENT IC
Solid Line – OFF Pulse Width > PWIN(off): Turn ON time t1.