C&H Technology PM150CL1A120 User Manual
Page 4

PM150CL1A120
Intellimod™ L-Series
Three Phase IGBT Inverter
150 Amperes/1200 Volts
2
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
03/10 Rev. 1
Absolute Maximum Ratings,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
PM150CL1A120
Units
Power Device Junction Temperature
T
j
-20 to 150
°C
Storage Temperature
T
stg
-40 to 125
°C
Mounting Torque, M5 Mounting Screws
—
31
in-lb
Mounting Torque, M5 Main Terminal Screws
—
31
in-lb
Module Weight (Typical)
—
800
Grams
Supply Voltage, Surge (Applied between P - N)
V
CC(surge)
1000
Volts
Self-protection Supply Voltage Limit (Short Circuit protection Capability)*
V
CC(prot.)
800
Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal
V
ISO
2500
Volts
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V)
V
CES
1200
Volts
Collector Current (T
C
= 25°C) (Note 1)
±I
C
150
Amperes
Peak Collector Current (T
C
= 25°C)
±I
CP
300
Amperes
Collector Dissipation (T
C
= 25°C) (Note 1)
P
C
833
Watts
Control Sector
Supply Voltage (Applied between V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
)
V
D
20
Volts
Input Voltage (Applied between U
P
-V
UPC
, V
P
-V
VPC
, W
P
-V
WPC
, U
N
- V
N
- W
N
-V
NC
)
V
CIN
20
Volts
Fault Output Supply Voltage
V
FO
20
Volts
(Applied between U
FO
-V
UPC
, V
FO
-V
VPC
, W
FO
-V
WPC
, F
O
-V
NC
)
Fault Output Current (U
FO
, V
FO
, W
FO
, F
O
Terminals)
I
FO
20
mA
*V
D
= 13.5 ~ 16.5V, Inverter Part, T
j
= 125°C
X
Y
Note 1: T
C
(under the chip) Measurement Point
Arm
UP
VP
WP
UN
VN
WN
Axis
IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi
X
25.2 25.2 58.8 58.8 88.8 88.8 37.2 37.2 70.8 70.8 88.8 88.8
Y
57.1 46.8 57.1 46.8 57.1 46.8 28.4 38.6 28.4 38.6 28.4 38.6