Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

POW-R-BRIK™
Phase Control Modules
345-800 Amperes/400-3000 Volts

P-3

Typical Thermistor Circuit
Thermistor temperatures can be
measured using the following
circuit arrangement in conjunction
with a 5 volt source. Resistance
values for R1 and R2 are specified

for two operating temperature
ranges.

POW-R-BRIK™ Thermistor
Characteristics

Element
Average

Thermistor Thermistor Temperature
Resistance Temp. Steady State Dynamic

Ohms °C °C (Min.) °C (Max.)

12093 40 43 50

7337 50 53 60

4990 60 63 70

3324 70 73 80

2262 80 83 90

1569 90 93 100

1316 95 98 105

1109 100 103 110

938 105 108 115

797 110 113 120

680 115 118 125

582 120 123 130

500 125 128 135

431 130 133 140

Curve matched ±2% over temperature range of +40°C
to +125°C. Resistance tolerance specified at +125°C,
±6%.

Without self heating, 10mW maximum thermistor
dissipation.

Use “Sensor at Tj” ohms from characteristics for
recommended steady state overload trip resistance.

1.

Temperature range, 75°C
through 125°C
R1 = 3.5K ohms
R2 = 840 ohms
V0 = 2.5 volts at 100°C

2.

Temperature range, 90°C
through 140°C
R1 = 2.2K ohms
R2 = 500 ohms
V0 = 2.45 volts at 115°C

The output signal (V0) is

approximately 30 mv/°C over the
temperature range indicated.

R

1

R

2

V

O

5 VOLT SUPPLY

THERMISTOR GATES

POW-R-BRIK

CONTROL:
PROTECTION
CIRCUIT

TIME, t, (SECONDS)

TRANSIENT THERMAL IMPEDANCE

CHARACTERISTICS (JUNCTION-TO-CASE)

Z7A

10

-4

TRANSIENT THERMAL IMPEDANCE, Z

(J-C)

(t), (

o

C/WATT)

10

-1

10

-2

10

-3

10

-3

10

-2

10

-1

10

0

10

1

10

2

10

3

PER ELEMENT,
BOTH CONDUCTING
PER ELEMENT,
ONE CONDUCTING
PER MODULE,
BOTH CONDUCTING

TIME, t, (SECONDS)

TRANSIENT THERMAL IMPEDANCE

CHARACTERISTICS (JUNCTION-TO-CASE)

Z9A

10

-4

TRANSIENT THERMAL IMPEDANCE, Z

(J-C)

(t), (

o

C/WATT)

10

-1

10

-2

10

-3

10

-3

10

-2

10

-1

10

0

10

1

10

2

10

3

PER ELEMENT,
BOTH CONDUCTING
PER ELEMENT,
ONE CONDUCTING
PER MODULE,
BOTH CONDUCTING