C&H Technology PM100CVA120 User Manual
Page 3

PM100CVA120
Intellimod™ Module
Three Phase IGBT Inverter Output
100 Amperes/1200 Volts
432
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings,
T
j
= 25
°
C unless otherwise specified
Characteristics
Symbol
PM100CVA120
Units
Power Device Junction Temperature
T
j
-20 to 150
°
C
Storage Temperature
T
stg
-40 to 125
°
C
Case Operating Temperature
T
C
-20 to 100
°
C
Mounting Torque, M5 Mounting Screws (Typical)
—
17
in-lb
Mounting Torque, M5 Main Terminal Screws (Typical)
—
17
in-lb
Module Weight (Typical)
—
730
Grams
Supply Voltage (Applied between P - N)
V
CC(surge)
1000
Volts
Supply Voltage Protected by SC (V
D
= 13.5 ~16.5V, Inverter Part, T
j
= 125
°
C Start)
V
CC(prot.)
800
Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal
V
RMS
2500
Volts
Control Sector
Supply Voltage Applied between (V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
)
V
D
20
Volts
Input Voltage Applied between (U
P
, V
P
, W
P
, U
N
, V
N
, W
N
)
V
CIN
20
Volts
Fault Output Supply Voltage (Applied between F
O
-GND)
V
FO
20
Volts
Fault Output Current (Sink Current at F
O
Terminals)
I
FO
20
mA
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V)
V
CES
1200
Volts
Collector Current,
±
(T
C
= 25
°
C)
I
C
100
Amperes
Peak Collector Current,
±
(T
C
= 25
°
C)
I
CP
200
Amperes
Collector Dissipation (T
C
= 25
°
C)
P
C
595
Watts