C&H Technology PM150RSA060 User Manual
Page 5
![background image](/manuals/266773/5/background.png)
573
PM150RSA060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
150 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics,
T
j
= 25
°
C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Over Current Trip Level Inverter Part
OC
-20
°
C
≤
T
≤
125
°
C
210
300
—
Amperes
Over Current Trip Level Brake Part
65
88
—
Amperes
Short Circuit Trip Level Inverter Part
SC
-20
°
C
≤
T
≤
125
°
C
—
420
—
Amperes
Short Circuit Trip Level Brake Part
—
132
—
Amperes
Over Current Delay Time
t
off(OC)
V
D
= 15V
—
10
—
µ
S
Over Temperature Protection
OT
Trip Level
111
118
125
°
C
OT
R
Reset Level
—
100
—
°
C
Supply Circuit Under Voltage Protection
UV
Trip Level
11.5
12.0
12.5
Volts
UV
R
Reset Level
—
12.5
—
Volts
Supply Voltage
V
D
Applied between V
UP1
-V
UPC
,
13.5
15
16.5
Volts
V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
Circuit Current
I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
—
52
72
mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
—
13
18
mA
Input ON Threshold Voltage
V
CIN(on)
Applied between
1.2
1.5
1.8
Volts
Input OFF Threshold Voltage
V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
, B
r
1.7
2.0
2.3
Volts
PWM Input Frequency
f
PWM
3-
л
Sinusoidal
—
15
20
kHz
Fault Output Current
I
FO(H)
V
D
= 15V, V
FO
= 15V
—
—
0.01
mA
I
FO(L)
V
D
= 15V, V
FO
= 15V
—
10
15
mA
Minimum Fault Output Pulse Width
t
FO
V
D
= 15V
1.0
1.8
—
mS
Brake Sector
Collector-Emitter Saturation Voltage
V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 150A,
—
2.7
3.5
Volts
T
j
= 25
°
C
V
D
= 15V, V
CIN
= 0V, I
C
= 150A,
—
2.5
3.4
Volts
T
j
= 125
°
C
Diode Forward Voltage
V
FM
-I
C
= 50A, V
D
= 15V, V
CIN
= 15V
—
1.7
2.5
Volts
Collector Cutoff Current
I
CES
V
CE
= V
CES
, T
j
= 25
°
C
—
—
1
mA
V
CE
= V
CES
, T
j
= 125
°
C
—
—
10
mA