C&H Technology PS21267-AP User Manual
Page 6
5
PS21267-P / PS21267-AP
Intellimod™ Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
08/10 Rev. 01
Recommended Conditions for Use
Characteristic
Symbol
Condition
Min.
Typ. Max. Units
Supply Voltage
V
CC
Applied between P-N
0
300 400 Volts
Control Supply Voltage
V
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
13.5
15.0 16.5 Volts
V
DB
Applied between
13.0
15.0 18.5 Volts
V
UFB
-V
UFS
,
V
VFB
-V
VFS
, V
WFB
-V
WFS
Control Supply Variation
Δ
V
D
,
Δ
V
DB
—
-1
—
1 Volts/μs
PWM Input Frequency
f
PWM
T
C
≤ 100°C, T
j
≤ 125°C
—
—
20
kHz
Allowable rms Current*
I
O
V
CC
= 300V, V
D
= V
DB
= 15V, f
PWM
= 5kHz,
—
—
19.1 Arms
PF = 0.8, Sinusoidal, T
j
≤ 125°C, T
C
≤ 100°C
V
CC
= 300V, V
D
= V
DB
= 15V, f
PWM
= 15kHz,
—
—
11.6 Arms
PF = 0.8, Sinusoidal, T
j
≤ 125°C, T
f
≤ 100°C
Minimum Input
P
WIN(on)
**
—
0.3
—
—
µs
Pulse Width
P
WIN(off)***
Below Rated Current
200 ≤ V
CC
≤ 350V,
1.5
—
—
µs
Between Rated Current
13.5 ≤ V
D
≤ 16.5V,
3.0
—
—
µs
& 1.7 Times of Rated Current
13.0 ≤ V
DB
≤ 18.5V,
Between 1.7 Times of Rated
-20°C ≤ T
C
≤ 100°C,
3.6
—
—
µs
& 2.0 Times of Rated Current
N-line Wiring Inductance Less Than 10nH
V
NC
Variation
V
NC
Between V
NC
-N (Including Surge)
-5.0
—
5.0
Volts
Arm Shoot-through
t
DEAD
For Each Input Signal, T
C
< 100°C
2
—
—
µs
Blocking Time
* The allowable rms current value depends on the actual application conditions.
**If input signal ON pulse is less than PWIN(on), the device may not respond.
***The IPM may fail to respond to an ON pulse if the preceeding OFF pulse is less than PWIN(off).