Absolute maximum ratings, t, 25°c unless otherwise specified, Igbt inverter sector – C&H Technology PS22054 User Manual
Page 3: Control sector

PS22054
Intellimod™ Module
Dual-In-Line Intelligent Power Module
15 Amperes/1200 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
2
Rev. 10/05
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics
Symbol
PS22054
Units
Power Device Junction Temperature*
T
j
-20 to 125
°C
Module Case Operation Temperature (See Note 1)
T
C
-20 to 100
°C
Storage Temperature
T
stg
-40 to 125
°C
Mounting Torque, M4 Mounting Screws
—
13
in-lb
Module Weight (Typical)
—
77
Grams
Self-protection Supply Voltage Limit (Short Circuit Protection Capability)**
V
CC(prot.)
800
Volts
Heatsink Flatness (See Note 2)
-50 to 100
µm
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal, Connection Pins to Heatsink Plate
V
ISO
2500
Volts
*The maximum junction temperature rating of the power chips integrated within the DIP-IPM is 150°C (@T
C
≤ 100°C). However, to ensure safe operation of the DIP-IPM,
the average junction temperature should be limited to T
j(avg)
≤ 125°C (@T
C
≤ 100°C).
**V
D
= 13.5 ~ 16.5V, Inverter Part, T
j
= 125°C, Non-repetitive, Less than 2µs
IGBT Inverter Sector
Collector-Emitter Voltage
V
CES
1200
Volts
Collector Current (T
C
= 25°C)
±I
C
15
Amperes
Peak Collector Current (T
C
= 25°C, <1ms)
±I
CP
30
Amperes
Supply Voltage (Applied between P-NU, NV, NW)
V
CC
900
Volts
Supply Voltage, Surge (Applied between P-NU, NV, NW)
V
CC(surge)
1000
Volts
Collector Dissipation (T
C
= 25°C, per 1 Chip)
P
C
56.8
Watts
Control Sector
Supply Voltage (Applied between V
P1
-V
PC
, V
N1
-V
NC
)
V
D
20
Volts
Supply Voltage (Applied between V
UFB
-V
UFS
,
V
VFB
-V
VFS
, V
WFB
-V
WFS
)
V
DB
20
Volts
Input Voltage (Applied between U
P
, V
P
, W
P
-V
PC
, U
N
, V
N
, W
N
-V
NC
)
V
IN
-0.5 ~ V
D
+0.5
Volts
Fault Output Supply Voltage (Applied between F
O
-V
NC
)
V
FO
-0.5 ~ V
D
+0.5
Volts
Fault Output Current (Sink Current at F
O
Terminal)
I
FO
1
mA
Current Sensing Input Voltage (Applied between C
IN
-V
NC
)
V
SC
-0.5 ~ V
D
+0.5
Volts
TC POINT
POWER TERMINALS
CONTROL TERMINALS
HEATSINK
BOUNDARY
Note 1 – T
C
Measure Point
Note 2 – Flatness Measurement Position
HEATSINK
MEASUREMENT POINT
3.25mm
HEATSINK
–
+
–
+