C&H Technology PM75B4L1C060 User Manual
Page 4

PM75B4L1C060
Photo Voltaic IPM
H-Bridge
75 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
3
03/11 Rev. 0
Electrical and Mechanical Characteristics,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Inverter Part
Collector-Emitter Saturation Voltage
V
CE(sat)
V
D
= 15V, I
C
= 75A, V
CIN
= 0V,
—
2.2
2.7
Volts
Pulsed, T
j
= 25°C
V
D
= 15V, I
C
= 75A, V
CIN
= 0V,
—
2.2
2.7
Volts
Pulsed, T
j
= 125°C
Emitter-Collector Voltage
V
EC
I
E
= 75A, V
D
= 15V, V
CIN
= 15V
—
2.4
3.3
Volts
Switching Times
t
on
0.1
0.5
1.2
µs
t
rr
V
D
= 15V, V
CIN
= 0 ↔ 15V
— 0.1 0.2 µs
t
C(on)
V
CC
= 300V, I
C
= 75A,
—
0.15
0.3
µs
t
off
T
j
= 125°C, Inductive Load
—
1.1
2.0
µs
t
C(off)
—
0.2
0.4
µs
Collector-Emitter Cutoff Current
I
CES
V
CE
= V
CES
, V
D
= 15V, V
CIN
= 15V, T
j
= 25°C —
—
1.0
mA
V
CE
= V
CES
, V
D
= 15V,
—
—
10
mA
V
CIN
= 15V, T
j
= 125°C
Control Part
Circuit Current
I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
— 6.5 12 mA
V
D
= 15V, V
CIN
= 15V, V
*P1
-V
*PC
— 1.6 4 mA
Input ON Threshold Voltage
V
th(on)
Applied between U
P
-V
UPC
,
1.2 1.5 1.8 Volts
Input OFF Threshold Voltage
V
th(off)
V
P
-V
VPC
, U
N
- V
N
- W
N
-Br-V
NC
1.7 2.0 2.3 Volts
Short Circuit Trip Level
SC
-20°C ≤ T
j
≤ 125°C, V
D
= 15V
112
—
—
Amperes
Short Circuit Current Delay Time
t
off(SC)
V
D
= 15V
—
0.2
—
µs
Over Temperature Protection
OT
Trip Level
135
—
—
°C
(Detect Temperature of IGBT)
OT
(hys)
Hysteresis
— 20 — °C
Supply Circuit Under-voltage Protection
UV
t
Trip Level
11.5
12.0
12.5
Volts
(-20°C ≤ T
j
≤ 125°C)
UV
r
Reset
Level
— 12.5 — Volts
Fault Output Current
I
FO(H)
V
D
= 15V, V
FO
= 15V
—
—
0.01
mA
I
FO(L)
V
D
= 15V, V
FO
= 15V
—
10
15
mA
Fault Output Pulse Width*
2
t
FO
V
D
= 15V
1.0
1.8
—
ms
*2 Fault output is given only when the internal SC, OT and UV protections schemes of either upper or lower devide operate to protect it.
Fault output of SC protection given pulse. Fault output of OT, UV protection given pulse while over trip level.