Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics
Symbol
PM450CLA120
Units
Power Device Junction Temperature
T
j
-20 to 150
°C
Storage Temperature
T
stg
-40 to 125
°C
Mounting Torque, M5 Mounting Screws
—
31
in-lb
Mounting Torque, M6 Main Terminal Screws
—
40
in-lb
Module Weight (Typical)
—
1250
Grams
Supply Voltage, Surge (Applied between P - N)
V
CC(surge)
1000
Volts
Self-protection Supply Voltage Limit (Short Circuit protection Capability)*
V
CC(prot.)
800
Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal
V
ISO
2500
Volts
*VD = 13.5 ~ 16.5V, Inverter Part, Tj = 125°C
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V)
V
CES
1200
Volts
Collector Current (T
C
= 25°C)
±I
C
450
Amperes
Peak Collector Current (T
C
= 25°C)
±I
CP
900
Amperes
Collector Dissipation (T
C
= 25°C)
P
C
2500
Watts
Control Sector
Supply Voltage (Applied between V
UP1
-V
UPC
, V
VP1
-V
VPC
,
V
D
20
Volts
V
WP1
-V
WPC
, V
UN1
-V
UNC
, V
WN1
-V
WNC
, V
N1
-V
NC
)
Input Voltage (Applied between U
P
-V
UPC
, V
P
-V
VPC
, W
P
-V
WPC
,
V
CIN
20
Volts
U
N
-V
UNC
, V
N
-V
VNC
, W
N
-V
WNC
)
Fault Output Supply Voltage (Applied between U
PFO
-V
UPC
, V
PFO
-V
VPC
,
V
FO
20
Volts
W
PFO
-V
WPC
, U
NFO
-V
UNC
, V
NFO
-V
VNC
, W
NFO
-V
WNC
)
Fault Output Sink Current at U
PFO
, V
PFO
, W
PFO
, U
NFO
, V
NFO
, W
NFO
Terminals
I
FO
20
mA