649
PM100DSA120
Intellimod™ Module
Single Phase IGBT Inverter Output
100 Amperes/1200 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics,
T
j
= 25
°
C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Over Current Trip Level Inverter Part
OC
-20
°
C
≤
T
≤
125
°
C
145
230
—
Amperes
Short Circuit Trip Level Inverter Part
SC
-20
°
C
≤
T
≤
125
°
C
200
340
—
Amperes
Over Current Delay Time
t
off(OC)
V
D
= 15V
—
5
—
µ
S
Over Temperature Protection
OT
Trip Level
100
110
120
°
C
OT
R
Reset Level
85
95
105
°
C
Supply Circuit Under Voltage Protection
UV
Trip Level
11.5
12.0
12.5
Volts
UV
R
Reset Level
—
12.5
—
Volts
Supply Voltage
V
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
13.5
15
16.5
Volts
Circuit Current
I
D
V
D
= 15V, V
CIN
= 5V, V
N1
-V
NC
—
19
26
mA
V
D
= 15V, V
CIN
= 5V, V
XP1
-V
XPC
—
19
26
mA
Input ON Threshold Voltage
V
CIN(on)
Applied between
1.2
1.5
1.8
Volts
Input OFF Threshold Voltage
V
CIN(off)
C
P1
-V
PC
, C
N1
-V
NC
1.7
2.0
2.3
Volts
PWM Input Frequency
f
PWM
3-
л
Sinusoidal
—
15
20
kHz
Fault Output Current
I
FO(H)
V
D
= 15V, V
FO
= 15V
—
—
0.01
mA
I
FO(L)
V
D
= 15V, V
FO
= 15V
—
10
15
mA
Minimum Fault Output Pulse Width
t
FO
V
D
= 15V
1.0
1.8
—
mS
SXR Terminal Output Voltage
V
SXR
T
j
≤
125
°
C, Rin = 6.8 k
⍀
(S
PR
, S
NR
)
4.5
5.1
5.6
Volts