C&H Technology PS21A7A User Manual
Page 4
PS21A7A
Intellimod™ Module
Dual-In-Line Intelligent Power Module
75 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
3
Rev. 08/09
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage
V
CE(sat)
I
C
= 75A, T
j
= 25°C, V
D
= V
DB
= 15V, V
IN
= 5V
—
1.55
2.05
Volts
I
C
= 75A, T
j
= 125°C, V
D
= V
DB
= 15V, V
IN
= 5V
—
1.65
2.10
Volts
Diode Forward Voltage
V
EC
T
j
= 25°C, -I
C
= 75A, V
IN
= 0V
—
1.70
2.20
Volts
Inductive Load Switching Times
t
on
1.80
2.40
—
µs
t
rr
V
CC
= 300V, V
D
= V
DB
= 15V,
—
0.30
—
µs
t
C(on)
I
C
= 75A, T
j
= 125°C, V
IN
= 0 ⇔ 5V,
—
0.40
—
µs
t
off
Inductive Load (Upper-Lower Arm)
—
3.40
—
µs
t
C(off)
—
0.65
—
µs
Collector-Emitter Cutoff Current
I
CES
V
CE
= V
CES
, T
j
= 25°C
—
—
1.0
mA
V
CE
= V
CES
, T
j
= 125°C
—
—
10
mA
Control Sector
Circuit Current
I
D
V
D
= V
DB
= 15V, V
IN
= 5V,
—
—
7.00
mA
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= V
DB
= 15V, V
IN
= 5V,
—
—
0.55
mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
V
D
= V
DB
= 15V, V
IN
= 0V,
—
—
7.00
mA
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= V
DB
= 15V, V
IN
= 0V,
—
—
0.55
mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
Fault Output Voltage
V
FOH
V
SC
= 0V, F
O
Terminal Pull-up to 5V by 10kΩ
4.9
—
—
Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA
—
—
0.95
Volts
Input Current
I
IN
V
IN
= 5V
1.0
1.5
2.0
mA
Short-Circuit Trip Level*
I
SC
-20°C ≤ T
C
≤ 100°C, V
D
= 15V, R
S
= 18.7Ω
127.5
—
225.0
Amps
Supply Circuit Undervoltage
UV
DBt
Trip Level, T
C
≤ 100°C
10.0
—
12.0
Volts
Protection
UV
DBr
Reset Level, T
C
≤ 100°C
10.5
—
12.5
Volts
UV
Dt
Trip Level, T
C
≤ 100°C
10.3
—
12.5
Volts
UV
Dr
Reset Level, T
C
≤ 100°C
10.8
—
13.0
Volts
Fault Output Pulse Width**
t
FO
C
FO
= 22nF
1.0
1.8
—
ms
ON Threshold Voltage
V
th(on)
Applied between U
P
, V
P
, W
P
-V
PC,
2.1
2.3
2.6
Volts
OFF Threshold Voltage
V
th(off)
U
N
, V
N
, W
N
-V
NC
0.8
1.4
2.1
Volts
Temperature Output***
V
OT
At LVIC Temperature = 85°C
3.50
3.63
3.76
Volts
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 85A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width t
FO
depends on the capacitance value
of C
FO
according to the following approximate equation: C
FO
= (12.2 x 10
-6
x t
FO
[F]).
***When the temperature rises excessively, the controller (MCU) should stop the DIPIPM.