C&H Technology PM75CSA120 User Manual
Page 5

PM75CSA120
Intellimod™ Module
Three Phase IGBT Inverter Output
75 Amperes/1200 Volts
514
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics,
T
j
= 25
°
C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector Cutoff Current
I
CEX
V
CE
= V
CEX
, T
j
= 25
°
C
—
—
1.0
mA
V
CE
= V
CEX
, T
j
= 125
°
C
—
—
10
mA
Diode Forward Voltage
V
FM
-I
C
= 75A, V
D
= 15V, V
CIN
= 0V
—
2.5
3.5
Volts
Collector-Emitter Saturation Voltage
V
CE(sat)
V
D
= 15V, V
CIN
= 15V, I
C
= 75A
—
2.5
3.5
Volts
V
D
= 15V, V
CIN
= 15V, I
C
= 75A,
—
2.2
3.2
Volts
T
j
= 125
°
C
Inductive Load Switching Times
t
on
0.5
1.0
2.5
µ
S
t
rr
V
D
= 15V, V
CIN
= 0 ~ 15V
—
0.15
0.3
µ
S
t
C(on)
V
CC
= 600V, I
C
= 75A
—
0.4
1.0
µ
S
t
off
T
j
= 125
°
C
—
2.0
3.0
µ
S
t
C(off)
—
0.7
1.2
µ
S
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Case Thermal Resistance
R
th(j-c)Q
Each IGBT
—
—
0.25
°
C/Watt
R
th(j-c)D
Each FWDi
—
—
0.51
°
C/Watt
Contact Thermal Resistance
R
th(c-f)
Case to Fin Per Module,
—
—
0.027
°
C/Watt
Thermal Grease Applied
Recommended Conditions for Use
Characteristic
Symbol
Condition
Value
Units
Supply Voltage
V
CC
Applied across P-N Terminals
0 ~ 800
Volts
V
D
Applied between V
UP1
-V
UPC
,
15
±
1.5
Volts
V
N1
-V
NC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
Input ON Voltage
V
CIN(on)
Applied between
0 ~ 0.8
Volts
Input OFF Voltage
V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
4.0 ~ V
D
Volts
PWM nput Frequency
f
PWM
Using Application Circuit
5 ~ 20
kHz
Minimum Dead Time
t
DEAD
Input Signal
≥
2.5
µ
S