Mb series, Vishay high power products, Single phase bridge (power modules), 25/35 a – C&H Technology 36MB Series User Manual
Page 5

www.vishay.com
For technical questions, contact: [email protected]
Document Number: 93563
4
Revision: 27-Jun-08
MB Series
Vishay High Power Products
Single Phase Bridge
(Power Modules), 25/35 A
Fig. 6 - Current Ratings Characteristics
Fig. 7 - Forward Voltage Drop Characteristics
Fig. 8 - Total Power Loss Characteristics
Fig. 9 - Maximum Non-Repetitive Surge Current
Fig. 10 - Maximum Non-Repetitive Surge Current
Average Forward Current (A)
Maximum Allowable Case temperature (°C)
50
70
90
110
130
150
0
5
10
15
20
25
30
35
40
180°
(Rect)
180°
(Sine)
36MB..A Series
Instantaneous Forward Voltage (V)
Instantaneous Forward Current (A)
1
10
100
1000
0.5
1
1.5
2
2.5
3
3.5
T
J
= 25 °C
T
J
= 150 °C
36MB..A Series
Average Forward Current (A)
Maximum Average Forward Power Loss (W)
Maximum Allowable Ambient Temperature (°C)
35
25
50
75
100
125
15
0
1 K/
W
2 K/
W
3 K/
W
4 K/
W
5 K/W
7 K/W
RthSA
= 0.7 K/
W
- Delt
a R
0
20
40
60
80
0
5
10
15
20
25
30
180°
(Sine)
180°
(Rect)
36MB..A Series
T
J
= 150 °C
Number of Equal Amplitude Half Cycle Current Pulses (N)
Peak Half Sine Wave Forward Current (A)
100
150
200
250
300
350
400
450
1
10
100
At Any Rated Load Condition And With
Rated V
RRM
Applied Following Surge.
Initial T
J
= 150 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
36MB..A Series
Peak Half Sine Wave Forward Current (A)
Pulse Train Duration (s)
100
150
200
250
300
350
400
450
500
0.01
0.1
1
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Initial T
J
= 150 °C
No Voltage Reapplied
Rated V
RRM
Reapplied
36MB..A Series