Vsk.91..pbf series, Vishay high power products, Standard diodes, 100 a (add-a-pak – C&H Technology VSK.91..PbF Series User Manual
Page 3: Generation 5 power modules)

www.vishay.com
For technical questions, contact: [email protected]
Document Number: 94359
2
Revision: 04-Jul-08
VSK.91..PbF Series
Vishay High Power Products
Standard Diodes, 100 A
(ADD-A-PAK
TM
Generation 5 Power Modules)
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
TYPE NUMBER
VOLTAGE
CODE
V
RRM
, MAXIMUM
REPETITIVE PEAK
REVERSE VOLTAGE
V
V
RSM
, MAXIMUM
NON-REPETITIVE PEAK
REVERSE VOLTAGE
V
I
RRM
MAXIMUM
AT T
J
= 150 °C
mA
VSK.91
04
400
500
10
06
600
700
08
800
900
10
1000
1100
12
1200
1300
14
1400
1500
16
1600
1700
FORWARD CONDUCTION
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum average forward current
at case temperature
I
F(AV)
180° conduction, half sine wave
100
A
100
°C
Maximum RMS forward current
I
F(RMS)
DC at 90 °C case temperature
157
A
Maximum peak, one-cycle
forward, non-repetitive
surge current
I
FSM
t = 10 ms
No voltage
reapplied
Sinusoidal half wave,
initial T
J
= T
J
maximum
2020
t = 8.3 ms
2110
t = 10 ms
100 % V
RRM
reapplied
1700
t = 8.3 ms
1780
Maximum I
2
t for fusing
I
2
t
t = 10 ms
No voltage
reapplied
20.43
kA
2
s
t = 8.3 ms
18.65
t = 10 ms
100 % V
RRM
reapplied
14.45
t = 8.3 ms
13.19
Maximum I
2
√t for fusing
I
2
√t
t = 0.1 to 10 ms, no voltage reapplied
204.3
kA
2
√s
Low level value of threshold voltage
V
F(TO)1
(16.7 % x
π x I
F(AV)
< I <
π x I
F(AV)
), T
J
= T
J
maximum
0.79
V
High level value of threshold voltage
V
F(TO)2
(I >
π x I
F(AV)
), T
J
= T
J
maximum
0.87
Low level value of forward
slope resistance
r
f1
(16.7 % x
π x I
F(AV)
< I <
π x I
F(AV)
), T
J
= T
J
maximum
1.78
m
Ω
High level value of forward
slope resistance
r
f2
(I >
π x I
F(AV)
), T
J
= T
J
maximum
1.57
Maximum forward voltage drop
V
FM
I
FM
=
π x I
F(AV)
, T
J
= 25 °C, t
p
= 400 µs square wave
1.45
V
BLOCKING
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum peak reverse
leakage current
I
RRM
T
J
= 150 °C
10
mA
RMS insulation voltage
V
INS
50 Hz, circuit to base, all terminals shorted
3500 (1 s)
V