C&H Technology PM150RSD120 User Manual
Page 5

PM150RSD120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
150 Amperes/1200 Volts
4
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Case Thermal Resistance
R
th(j-c)Q
Each IGBT
—
—
0.16
°
C/Watt
Inverter Part
R
th(j-c)F
Each FWDi
—
—
0.24
°
C/Watt
R
th(j-c´)Q
Each IGBT*
—
—
0.10**
°
C/Watt
R
th(j-c´)F
Each FWDi*
—
—
0.16**
°
C/Watt
Junction to Case Thermal Resistance
R
th(j-c)Q
Each IGBT
—
—
0.30
°
C/Watt
Brake Part
R
th(j-c)F
Each FWDi
—
—
0.80
°
C/Watt
R
th(j-c´)Q
Each IGBT*
—
—
0.22**
°
C/Watt
R
th(j-c´)F
Each FWDi*
—
—
0.36**
°
C/Watt
Contact Thermal Resistance
R
th(c-f)
Case to Fin Per Module,
—
—
0.018
°
C/Watt
Thermal Grease Applied
*T
C
measured point is just under the chips.
**If you use this value, R
th(f-a)
should be mesured just under the chips.
Recommended Conditions for Use
Characteristic
Symbol
Condition
Value
Units
Supply Voltage
V
CC
Applied across P-N Terminals
0 ~ 800
Volts
Control Supply Voltage***
V
D
Applied between V
UP1
-V
UPC
,
15
±
1.5
Volts
V
N1
-V
NC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
Input ON Voltage
V
CIN(on)
Applied between U
P
-V
UPC
, V
P
-V
VPC
,
0 ~ 0.8
Volts
Input OFF Voltage
V
CIN(off)
W
P
-V
WPC
, U
N,
V
N
, W
N,
B
r
-V
NC
4.0 ~ V
D
Volts
PWM Input Frequency
f
PWM
Using Application Circuit
0 ~ 20
kHz
Minimum Dead Time
t
DEAD
Input Signal
≥
3.0
µ
S
***With ripple satisfying the following conditions: dv/dt
≤
±
5v/
µ
s, Variation
≤
2V peak to peak.