VEGA VEGASWING 66 - Relay User Manual
Page 28
28
9 Supplement
VEGASWING 66 • - Relay
43756-EN-130322
Ʋ Tube extension
approx. 1100 g/m (11.8 oz/ft)
Surface quality
R
a
approx. 3 µm (1.18
-4
in)
Process fittings
Ʋ Pipe thread, cylindrical (DIN 3852-A) G1
Ʋ American pipe thread, conical
(ASME B1.20.1)
1 NPT
Ʋ Flanges
DIN EN from DN 40, ANSI from 2"
Max. torque - process fitting
Ʋ Thread G1, 1 NPT
max. 285 Nm (210 lbf ft)
1)
Output variable
Output
Relay output (2 x SPDT), 2 floating spdts
Switching voltage
Ʋ Min.
10 mV
Ʋ Max.
253 V AC, 253 V DC
Switching current
Ʋ Min.
10 µA
Ʋ Max.
5 A AC, 1 A DC
Breaking capacity
Ʋ Min.
50 mW
Ʋ Max.
1250 VA AC, 40 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact surface will
be permanently damaged. The contact is then no longer
suitable for switching low-level signal circuits.
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
Ʋ Max.
Max. detection or overflow/overfill protection
Ʋ Min.
Min. detection or dry run protection
Accuracy (according to DIN EN 60770-1)
Reference conditions and actuating variables according to DIN EN 61298-1
Ʋ Ambient temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ Relative humidity
45 … 75 %
Ʋ Air pressure
860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)
Ʋ Product temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ Product density
1 g/cm³ (0.036 lbs/in³) (water)
Ʋ Product viscosity
1 mPa s
Ʋ Superimposed pressure
0 kPa
Ʋ Sensor installation
Vertically from top
Ʋ Density selection switch
> 0.7 g/cm³
1)
Depending on the mounting boss of the vessel