3 Product description

SOLITRAC 31 • 4 … 20 mA/HART - four-wire

43387-EN-131119

Due to the physical properties of the radioactive radiation, the pulse

rate is subject to slight fluctuations. Set a suitable damping level to get

a stable measured value.

The relation between level and the pulse rate measured by the sensor

is not linear.
Set up a linearization table to get a linear level signal. For precise

mesurement results, make sure when setting up the linearization

table that the actual filling height of the measuring points is entered as

exactly as possible.

External radiation sources can influence the measured value (e.g.

welding joint tests). In safety-relevant applications, the safety function

must be treated as unreliable as long as the external radiation occurs.
If necessary, you must take measures to maintain the safety function.

Make sure during the planning that for the planned application, a

possibly large different of the pulse rate with empty and full vessel is

reaced. This applies mainly for products with low density or in vessels

with extremely small diameter.

3.4 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

based on ISO 4180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Transport must be carried out in due consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.
Unless otherwise indicated, the packages must be stored only under

the following conditions:

Not in the open

Dry and dust free

Not exposed to corrosive media

Protected against solar radiation

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Non-linearity of the pro-

cess value

External radiation

Span

Packaging

Transport

Transport inspection

Storage

Storage and transport

temperature