VEGA SOLITRAC 31 4 … 20 mA_HART - four-wire With SIL qualification User Manual
Page 76
76
11 Supplement
SOLITRAC 31 • 4 … 20 mA/HART - four-wire
43387-EN-131119
Process temperature (measured on the
detector tube)
-40 … +60 °C (-40 … +140 °F)
With temperatures of more than 60 °C we recommend
the use of water cooling
Vibration resistance
6)
mechanical vibrations up to 1 g in the frequency range
5 … 200 Hz
Electromechanical data - version IP 66/IP 67
Cable entry
Ʋ M20 x 1.5
2 x cable gland M20 x 1.5 (cable: ø 6 … 12 mm), 4 x
blind plug M20 x 1.5
Included: 1 x cable gland M20 x 1.5
Ʋ ½ NPT
5 x closing cap (red) ½ NPT
Included: 3 x cable gland ½ NPT (cable: ø 6 … 12 mm),
4 x blind plug ½ NPT
Spring-loaded terminals for wire cross-section
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Display and adjustment module
Display element
Display with backlight
Measured value indication
Ʋ Number of digits
5
Ʋ Size of digits
W x H = 7 x 13 mm
Adjustment elements
4 keys
Protection rating
Ʋ unassembled
IP 20
Ʋ mounted into the housing without
cover
IP 40
Materials
Ʋ Housing
ABS
Ʋ Inspection window
Polyester foil
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone Ex factory
CET
Rate deviation max.
10.5 min/year
Measurement electronics temerature
Resolution
1 °C (1.8 °F)
Accuracy
±1 °C (1.8 °F)
6)
Tested according to the guidelines of German Lloyd, GL directive 2.