beautypg.com

VEGA VEGAFLEX 83 4 … 20 mA_HART - four-wire Polished version User Manual

Page 69

background image

69

11 Supplement

VEGAFLEX 83 • 4 … 20 mA/HART - four-wire

41840-EN-130314

Torque for exchangeable rod probe (in

the process fitting)

4.5 Nm ±0.5 (3.32 lbf ft)

Torque for NPT cable glands and Conduit tubes

Ʋ Plastic housing

max. 10 Nm (7.376 lbf ft)

Ʋ Aluminium/Stainless steel housing

max. 50 Nm (36.88 lbf ft)

Input variable
Measured variable

Level of liquids

Min. dielectric constant of the medium

ε

r

≥ 1.6

2

4

5

3

1

Fig. 35: Measuring ranges - VEGAFLEX 83
1 Reference plane

2 Probe length L

3 Measuring range (default setting refers to the measuring range in water)

4 Upper dead band (see diagrams under Accuracy - grey section)

5 Lower dead band (see diagrams under Accuracy - grey section)

Output variable
Output signals

4 … 20 mA/HART - active; 4 … 20 mA/HART - passive

Terminal voltage passive

9 … 30 V DC

Shortcircuit protection

Available

Potential separation

Available

Signal resolution

0.3 µA

Failure signal current output (adjustable) Last valid measured value, ≥ 21.0 mA, ≤ 3.6 mA
Max. output current

22 mA

Starting current

≤ 3.6 mA