VEGA VEGABAR 86 4 … 20 mA - Operating Instructions User Manual
Page 59
59
11 Supplement
VEGABAR 86 • 4 … 20 mA
45506-EN-131010
Ambient conditions
Version
Ambient temperature
Storage and transport temper-
ature
Version with connection tube
-40 … +80 °C (-40 … +176 °F)
-60 … +80 °C (-76 … +176 °F)
Version with suspension cable FEP,
PUR
-20 … +80 °C (-4 … +176 °F)
-20 … +80 °C (-4 … +176 °F)
Version with suspension cable PE
-20 … +60 °C (-4 … +140 °F)
-20 … +60 °C (-4 … +140 °F)
Version IP 68 (1 bar) with connec-
tion cable PE
-20 … +60 °C (-4 … +140 °F)
-20 … +60 °C (-4 … +140 °F)
Process conditions
Product temperature depending on the measuring cell seal
The specifications are an overview. The specification on the type plate are valid.
Version
Measuring cell seal
Product temperature
Suspension cable PE
FKM (VP2/A)
EPDM (A+P 75.5/KW75F)
-20 … +60 °C (-4 … +140 °F)
Suspension cable PUR
FKM (VP2/A)
EPDM (A+P 75.5/KW75F)
-20 … +80 °C (-4 … +176 °F)
Suspension cable FEP
FKM (VP2/A)
EPDM (A+P 75.5/KW75F)
-20 … +100 °C (-4 … +212 °F)
FFKM (Kalrez 6375)
-10 … +100 °C (+14 … +212 °F)
Connection tube
FKM (VP2/A)
EPDM (A+P 75.5/KW75F)
-20 … +100 °C (-4 … +212 °F)
FFKM (Kalrez 6375)
-10 … +100 °C (+14 … +212 °F)
Transmitter material PVDF
FKM (VP2/A)
EPDM (A+P 75.5/KW75F)
-20 … +60 °C (-4 … +140 °F)
FFKM (Kalrez 6375)
-10 … +60 °C (+14 … +140 °F)
Transmitter protection PE
FKM (VP2/A)
EPDM (A+P 75.5/KW75F)
-20 … +60 °C (-4 … +140 °F)
Mechanical stress, depending on the instrument version
Vibration resistance
4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
With version with connection tube, vibration resistance 1 g. With lengths > 0.5 m (1.64 ft) the tube
must be supported in addition.
Shock resistance
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ Cable gland
M20 x 1.5