Quick start
The quick start procedure enables a quick setup with many applica-
tions. You can find further information in the respective chapters of the
operating instructions manual.
1. Distance from the metallic vessel wall > 300 mm. Distance from
non-metallic vessel wall > 500 mm. The probe must not touch any
installations or the vessel wall.
2. In non-metallic vessels, place a metal sheet beneath the process
fitting.
1
2
Fig. 1: Installation in plastic silo
1 Flange
2 Metal sheet
3. If necessary, fasten probe end.
For further information see chapter "Mounting".
1. Make sure that the power supply corresponds to the specifica-
tions on the type label.
2. Connect the instrument according to the following illustration
5
1
2
+
( )
(-)
6 7 8
4...20mA
2
3
4
1
Fig. 2: Electronics and connection compartment, single chamber housing
1 Voltage supply, signal output
2 For display and adjustment module or interface adapter
3 For external display and adjustment unit
4 Ground terminal for connection of the cable screen
See also chapter "Connecting to power supply"
For standard applications we recommend selecting the "Quick setup"
in the display and adjustment module.
Mounting
Electrical connection
Set parameters