beautypg.com

10 supplement, 1 technical data – VEGA VEGABAR 53 Foundation Fieldbus User Manual

Page 45

background image

45

10 Supplement

VEGABAR 53 • Foundation Fieldbus

36724-EN-130321

10 Supplement

10.1 Technical data

General data
Pressure type

Gauge pressure or gauge pressure

Measuring principle

Depending on the measuring range piezoresistive with

internal transmission liquid or strain gauge (DMS) dry.

Communication interface

I²C bus

General data
Parameter, pressure

Gauge pressure, absolute pressure, vacuum

Measuring principle

Ceramic-capacitive, dry measuring cell

Communication interface

I²C bus

Materials and weights
Materials, wetted parts

Ʋ Process fitting

316Ti

Ʋ Diaphragm standard

316Ti

Ʋ Diaphragm from measuring range

25 bar, with not flush version

Elgiloy 2.4711

Ʋ Seal ring, O-ring

FKM (VP2/A), EPDM (A+P 75.5/KW75F), NBR (COG),

FFKM (Chemraz 535)

Material seal process fitting

Ʋ Thread G½ (EN 837)

Klingersil C-4400

Ʋ M44 x 1.25

FKM, FFKM, EPDM

Surface quality hygienic fittings, typ.

R

a

< 0.8 µm

Ʋ Surface quality, typ.

Materials, non-wetted parts

Ʋ Internal transmission liquid

Synthetic oil, Halocarbon oil

9)10)

Ʋ Electronics housing

Plastic PBT (polyester), Alu die-casting powder-coated,

316L

Ʋ External housing

plastic PBT (Polyester), 316L

Ʋ Socket, wall mounting plate external

housing

plastic PBT (Polyester), 316L

Ʋ Seal between socket and wall mount-

ing plate

EPDM (fixed connected)

Ʋ Seal below wall mounting plate

EPDM (only with 3A approval)

Ʋ Seal ring, housing cover

NBR (stainless steel housing), silicone (Alu/plastic hous-

ing)

Ʋ Inspection window in housing cover

for display and adjustment module

Polycarbonate (UL-746-C listed)

9)

Synthetic oil for measuring ranges up to 16 bar, FDA listed for the food processing industry. For measuring

ranges up to 25 bar dry measuring cell.

10)

Halocarbon oil: Generally in oxygen applications, not with vacuum measuring ranges, not with absolute meas-

uring ranges < 1 bar

abs

.