VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire User Manual
Page 70
70
11 Supplement
VEGAPULS 62 • 4 … 20 mA/HART - two-wire
36503-EN-121011
Ʋ Antenna impedance cone PEEK
-1 … 100 bar (-100 … 10000 kPa/-14.5 … 1450 psig)
Ʋ Antenna impedance cone ceramic
-1 … 160 bar (-100 … 16000 kPa/-14.5 … 2320 psig)
Vessel pressure - parabolic antenna
-1 … 6 bar (-100 … 6000 kPa/-14.5 … 870 psig)
Vessel pressure with swivelling holder
-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)
Vessel pressure relating to the flange
nominal stage
see supplementary instructions manual "Flanges ac-
cording to DIN-EN-ASME-JIS"
Vibration resistance
Ʋ Horn antenna
4 g at 5 … 200 Hz according to EN60068-2-6 (vibration
with resonance)
Ʋ Parabolic antenna
1 g at 5 … 200 Hz according to EN60068-2-6 (vibration
with resonance)
Shock resistance
Ʋ Horn antenna
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Ʋ Parabolic antenna
25 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Data on rinsing air connection
Pressure max.
6 bar (87.02 psig)
Air quantity without reflux valve, with
Ʋ 0.2 bar (2.9 psig)
2.0 m
3
/h
Ʋ 0.5 bar (7.25 psig)
3.5 m
3
/h
Ʋ 1 bar (14.5 psig)
4.5 m
3
/h
Ʋ 1.5 bar (21.76 psig)
5 m
3
/h
Ʋ 2 bar (29.0 psig)
5.5 m
3
/h
Thread
G⅛ A
Closure, with
Ʋ Non-Ex
Dust protection cover of PE
Ʋ Ex
Threaded plug of 316Ti
Reflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex
version)
Ʋ Material
316Ti
Ʋ Seal
FKM (Viton), FFKM (Kalrez 6375)
Ʋ for tube diameter
6 mm
Ʋ opening pressure
0.5 bar (7.25 psig)
Ʋ Nominal pressure stage
PN 250
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ Cable gland
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Ʋ Closing cap
M20 x 1.5; ½ NPT