beautypg.com

VEGA VEGAPULS 63 (≥ 2.0.0 - ≥ 4.0.0) Profibus PA User Manual

Page 16

background image

16

4 Mounting

VEGAPULS 63 • Profibus PA

36513-EN-130228

Fig. 8: Mounting of the radar sensor on vessels with conical bottom

Do not mount the instruments in or above the filling stream. Make sure

that you detect the product surface, not the inflowing product.

Fig. 9: Mounting of the radar sensor with inflowing medium

Flush mounting

The best way to mount the sensor, also with respect to cleanability, is

flush on a block flange (flange without socket piece) or with hygienic

fittings, e.g. Neumo Biocontrol.
Mounting on socket

If the reflective properties of the medium are good, you can mount

VEGAPULS 63 on a socket piece. You will find recommended values

for socket heights in the following illustration. The socket end should

be smooth and burr-free, if possible also rounded. Then carry out a

false echo storage.

Inflowing medium

Socket