beautypg.com

VEGA VEGAPULS 66 (≥ 2.0.0 - ≥ 4.0.0) Foundation Fieldbus User Manual

Page 36

background image

36

6 Set up with the indicating and adjustment module

VEGAPULS 66 • Foundation Fieldbus

36522-EN-121011

– Large distance to the medium

– Large angles of repose

Bunker with fast filling:

Vessel of concrete or metal, also multiple chamber silo:

– Structured vessel walls

– Installations present

Process/measurement conditions:

– Measured value jumps, e.g. by truck loading

– Large distance to the medium

– Large angles of repose

Heap:

Sensor mounting on movable conveyor belts

Detection of the heap profile

Height detection during filling

Process/measurement conditions:

– Measured value jumps, e.g. by the profile of the heap or trav-

erses

– Large angles of repose

– Measurement near the filling stream

Crusher:

Vessel: installations, wear and protective facilities available

Process/measurement conditions:

– Measured value jumps, e.g. by truck loading

– Fast reaction time

– Large distance to the medium

Demonstration:

Adjustment for all applications which are not typically level meas-

urement

Sensor accepts all measured value changes within the measuring

range immediately

Typical applications:

– Instrument demonstration

– Object recognition/monitoring (additional settings required)

Through this selection, the sensor is adapted optimally to the applica-

tion or the location and measurement reliability under the various

basic conditions is increased considerably.
Enter the requested parameters via the appropriate keys, save your

settings with [OK] and jump to the next menu item with the [ESC] and

the [->] key.

With this selection, the operating range of the sensor is adapted to

the vessel height and the reliability with different frame conditions is

increased considerably.
Independent from this, the min. adjustment must be carried out.

Setup/Vessel height,

measuring range