VEGA VEGAMIP T61 Emitting unit User Manual
Page 21
Frequency range
K band, 24.085 GHz (ISM band)
Measuring range
0.1 … 100 m (0.33 … 328 ft)
Beam angle
1)
-
Threaded version - internal horn antenna
(PTFE cover)
20°
-
Plastic encapsulated antenna with PP
cover
10°
-
Horn antenna (316L) - ø 40 mm (1.575 in)
22°
-
Horn antenna (316L) - ø 48 mm (1.89 in)
18°
-
Encapsulated antenna with PTFE cover -
Flange DN 50, ANSI 2"
18°
-
Encapsulated antenna with PTFE cover -
Flange DN 80 … DN 150, ANSI 3" … 6"
10°
Ambient conditions
Ambient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of bulk solids and liquids
Process pressure
2)
-
VEGAMIP
61, threaded version - internal
horn antenna with PTFE cover
-1 … 4 bar/-100 … 400 kPa (-14.5 … 58 psig)
-
VEGAMIP
61, plastic encapsulated an-
tenna with PP cover
-1 … 2 bar/-100 … 200 kPa (-14.5 … 29 psig)
-
VEGAMIP
61, horn antenna/316L
-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psig)
-
VEGAMIP
61, encapsulated horn anten-
na with PTFE cover
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
-
VEGAMIP
61 with mounting adapter
unpressurized (IP 67)
Process temperature (thread or flange tem-
perature)
-
VEGAMIP
61, threaded version - internal
horn antenna with PTFE cover
-40 … +80 °C (-40 … +176 °F)
-
VEGAMIP
61, plastic encapsulated an-
tenna with PP cover
-40 … +80 °C (-40 … +176 °F)
-
VEGAMIP
61, horn antenna/316L - seal:
FKM (SHS FDM 70C3 GLT)
-40 … +130 °C (-40 … +266 °F)
-
VEGAMIP
61, horn antenna/316L - seal:
FFKM (Kalrez 6375)
-20 … +130 °C (-4 … +266 °F)
1)
Outside the specified beam angle, the energy of the radar signal has a level
of -3 dB (50 %)
2)
Note max. pressure of the process fitting
VEGAMIP T
61 • Emitting unit
21
9 Supplement
36998
-
EN
-120228