63
11 Supplement
VEGAPULS 67 • Foundation Fieldbus
36534-EN-121011
Ʋ Max. spectral transmission power
density
+43 dBm/50 MHz EIRP
Ʋ Max. power density in a distance of
1 m
< 1 µW/cm²
Ambient conditions
Ambient, storage and transport tempera-
ture
-40 … +80 °C (-40 … +176 °F)
Process conditions
Process temperature (measured on the
process fitting)
-40 … +80 °C (-40 … +176 °F)
Vessel pressure
-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)
Vessel pressure - version with adapter
flange from DN 150 PP
-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)
Vibration resistance
4)
Ʋ Plastic horn antenna with compres-
sion or adapter flange
mechanical vibrations up to 2 g in the frequency range
5 … 200 Hz
Ʋ Plastic horn antenna with mounting
strap
mechanical vibrations up to 1 g in the frequency range
5 … 200 Hz
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ Cable gland
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Ʋ Closing cap
M20 x 1.5; ½ NPT
Plug options
Ʋ Signal circuit
M12 x 1, according to ISO 4400, Harting HAN, 7/8" FF
Ʋ Indication circuit
M12 x 1
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Options of the cable entry
Ʋ Cable gland with integrated connec-
tion cable
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Connection cable
Ʋ Wire cross-section
0.5 mm² (AWG 20)
Ʋ Wire resistance
< 0.036 Ω/m
Ʋ Tensile strength
< 1200 N (270 lbf)
4)
Tested according to the guidelines of German Lloyd, GL directive 2.