2 dimensions – VEGA VEGAPULS SR 68 4 … 20 mA_HART - four-wire User Manual
Page 71
71
11 Supplement
VEGAPULS SR 68 • 4 … 20 mA/HART - four-wire
38295-EN-130624
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone Ex factory
CET
Measurement electronics temerature
Resolution
1 °C (1.8 °F)
Accuracy
±1 °C (1.8 °F)
Voltage supply
Operating voltage
Ʋ Version for low voltage
9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz
Ʋ Version for mains voltage
90 … 253 V AC, 50/60 Hz
Interpolation protection
Integrated
Max. power consumption
4 VA; 2.1 W
Electrical protective measures
Protection, depending on housing version
Ʋ Plastic housing
IP 66/IP 67
Ʋ Aluminium housing, stainless steel
housing - investment casting, stain-
less steel housing - electro-polished
IP 66/IP 68 (0.2 bar)
4)
Ʋ Aluminium and stainless housing, in-
vestment casting (optionally available)
IP 66/IP 68 (1 bar)
Overvoltage category
III
Protection class
III
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.
They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as
well as under "Downloads" and "Approvals".
11.2 Dimensions
The following dimensional drawings represent only an extract of all possible versions. Detailed
dimensional drawings can be downloaded at www.vega.com/downloads under "Drawings".
4)
The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.