beautypg.com

3 mounting preparations - parabolic antenna – VEGA VEGAPULS SR 68 4 … 20 mA_HART - four-wire User Manual

Page 15

background image

15

4 Mounting

VEGAPULS SR 68 • 4 … 20 mA/HART - four-wire

38295-EN-130624

3. Insert the antenna from below into the vessel socket and secure it

against falling off

4. Retighten the antenna with hexagon screws to the antenna

socket; torque max. 2.5 Nm (1.8 lbf ft)

Note:

The radar sensor with rinsing air connection or antenna extension

is provided with a notch on the antenna socket. This notch must be

aligned with the marking on the process fitting (the marking specifies

the position of the polarisation of the radar signal).

3

4

1

2

Fig. 5: Dismounting of the horn antenna
1 Marking for the polarisation

2 Marking at the antenna socket

3 Hexagon screws on the antenna socket

4 Antenna

4.3 Mounting preparations - Parabolic antenna

The instrument is also available in versions where the antenna has

a diameter larger than the process fitting (thread, flange). With such

versions the antenna must be disconnected from the process fitting

before mounting. Proceed as follows:
1. Clamp VEGAPULS SR 68 with the flange, e.g. in a bench vice
2. Hold the connection piece (3) with a wrench on the flat surfaces

(width across flats 22 mm)

3. Loosen counter nut (2) completely with a wrench (width across

flats 36 mm) in the direction of the antenna

4. Loosen compression nut (1) completely with a wrench (width

across flats 41 mm) in the direction of the antenna

5. Remove the parabolic antenna (4) axially
6. Mount sensor flange on the adapter flange and fasten it tightly
7. Check if the O-ring seal is present on the connection piece and

make sure it is not damaged.