beautypg.com

VEGA VEGAPULS 66 (≥ 2.0.0 - ≥ 4.0.0) standpipe ver. Profibus PA User Manual

Page 49

background image

49

11 Supplement

VEGAPULS 66 standpipe version • Profibus PA

36525-EN-121011

Gas phase

Temperature

Pressure

1 bar

(14.5 psig)

10 bar

(145 psig)

50 bar

(725 psig)

100 bar

(1450 psig)

200 bar

(2900 psig)

Steam (satu-

rated steam)

100 °C/212 °F 0.26 %

-

-

-

-

180 °C/356 °F 0.17 %

2.1 %

-

-

-

264 °C/507 °F 0.12 %

1.44 %

9.2 %

-

-

366 °C/691 °F 0.07 %

1.01 %

5.7 %

13.2 %

76.0 %

Characteristics and performance data
Measuring frequency

C-band (6 GHz technology)

Measuring cycle time approx.

350 ms

Step response time

2)

≤ 3 s

Tracking speed of the measuring window

max.

1 m/min

Emitted HF power (depending on the parameter adjustment)

3)

Ʋ Average spectral transmission power

density

-31 dBm/MHz EIRP

Ʋ Max. spectral transmission power

density

+24 dBm/50 MHz EIRP

Ʋ Specific absorption rate (SAR)

0.47 mW/kg

Ambient conditions
Ambient, storage and transport tempera-

ture

-40 … +80 °C (-40 … +176 °F)

Process conditions
For the process conditions, please also note the specifications on the type label. The lower value

always applies.

Seal

Antenna impedance

cone

Process temperature (measured on the process

fitting)

FKM (A+P GLT FPM

70.16-06)

PFFE

-40 … +150 °C (-40 … +302 °F)

FFKM (Kalrez 6375)

PFFE

-20 … +150 °C (-4 … +302 °F)

Silicone FEP coated (A+P

FEP-O-SEAL)

PFFE

-40 … +150 °C (-40 … +302 °F)

EPDM (A+P 75.5/KW/75F) PFFE

-40 … +150 °C (-40 … +302 °F)

Graphite

Ceramic

-60 … +250 °C (-76 … +482 °F)

Ceramic

-60 … +300 °C (-76 … +572 °F)

Ceramic

-60 … +400 °C (-76 … +752 °F)

Vessel pressure relating to the antenna cone

Ʋ PTFE

-100 … 4000 kPa/-1 … 40 bar (-14.5 … 580 psi) with

PN 40

2)

Time span after a sudden measuring distance change by max. 0.5 m in liquid applications until the output signal

has taken for the first time 90 % of the final value (IEC 61298-2).

3)

EIRP: Equivalent Isotropic Radiated Power