General data
316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Process fitting
316L, Hastelloy C22, Monell Alloy
Ʋ Process seal
On site (instruments with thread: Klingersil C-4400 is
attached)
Ʋ Antenna
316L, Hastelloy C22, Tantalum, 316L electropolished,
stainless steel investment casting 1.4848, Monell Alloy,
316L Safecoat coated
Ʋ Antenna impedance cone
PTFE, PP, PEEK, ceramic (99.7 % Al
2
O
3
)
Ʋ seal, antenna system
FKM (SHS FPM 70C3 GLT), FFKM (Kalrez 6375), FFKM
(Kalrez 2035), FFKM (Kalrez 6230 - FDA), graphite
(99.9 %)
Materials, non-wetted parts
Ʋ Plastic housing
plastic PBT (Polyester)
Ʋ Aluminium die-casting housing
Aluminium die-casting AlSi10Mg, powder-coated - basis:
Polyester
Ʋ Stainless steel housing
316L
Ʋ Seal between housing and housing
cover
NBR (stainless steel housing, precision casting), silicone
(aluminium/plastic housing; stainless steel housng,
electropolished)
Ʋ Inspection window in housing cover
(optional)
Polycarbonate
Ʋ Ground terminal
316L
Ohmic contact
Between ground terminal, process fitting and antenna
Process fittings
Ʋ Pipe thread, cylindrical (ISO 228 T1) G1½ A according to DIN 3852-A
Ʋ American pipe thread, tapered
1½ NPT, 2 NPT
Ʋ Flanges
DIN from DN 25, ANSI from 1"
Weight
Ʋ Instrument (depending on housing,
process fitting and antenna)
approx. 2 … 17.2 kg (4.409 … 37.92 lbs)
Ʋ Antenna extension
1.6 kg/m (1.157 lbs/ft)
Length antenna extension max.
5.85 m (19.19 ft)
Torque for NPT cable glands and Conduit tubes
Ʋ Plastic housing
max. 10 Nm (7.376 lbf ft)
Ʋ Aluminium/Stainless steel housing