9 supplement, 1 technical data, 9supplement – VEGA EL 1 Conductive probe User Manual
Page 19
9
Supplement
9
.1 Technical data
General data
Materials 316Ti corresponds to 1.4571, 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
-
Process fitting
316L
-
Process seal
Klingersil C-4400
-
insulation (partly insulated)
PTFE
-
Electrode (rod, PTFE partly insulated)
316Ti, Hastelloy C4 (2.4610)
Materials, non-wetted parts
-
Housing
316Ti
-
Housing cover
PBT
-
Seal between housing and housing
cover
NBR
-
Cable gland
brass, nickel-plated
Process fitting
G½ A (ISO 228 T1)
Weight
-
with stainless steel housing
400 g (14 oz)
-
Rod weight: ø 8 mm (0.315 in)
400 g/m (4.3 oz/ft)
Sensor length (L)
-
Stainless steel (316Ti)
0.04 … 4 m (0.131 … 13.12 ft)
-
Hastelloy C4 (2.4610)
0.05 … 4 m (0.164 … 13.12 ft)
Insulation length (L1)
0.039 … 0.2 m (0.128 … 0.656 ft)
Output variable
Suitable signal conditioning instruments
VEGATOR 256C, 532, 631
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Process pressure
-1 … 63 bar/-100 … 6300 kPa (-14.5 … 914 psig)
Process temperature EL 1 of 316L
-50 … +130 °C (-58 … +266 °F)
Conductive of the medium
min. 7.5 µS/cm
Electromechanical data
Cable entry
1 x cable gland M16 x 1.5 (cable: ø 5 … 10 mm/
0.2 … 0.35 in)
Conductive probe EL 1
19
9 Supplement
32651
-
EN
-100208