Output variable
Output
Relay output (DPDT), 2 floating spdts
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.
Turn-on voltage
-
Min.
10 mV
-
Max.
253 V AC, 253 V DC
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.
Switching current
-
Min.
10 µA
-
Max.
3 A AC, 1 A DC
Breaking capacity
-
Min.
50 mW
-
Max.
750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
min./max.
Switching delay
-
When immersed
0.5 s
-
When laid bare
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of solids
Process pressure
-1 … 25 bar/-100 … 2500 kPa (-14.5 … 363 psig)
VEGAWAVE
61 of 316L
-50 … +150 °C (-58 … +302 °F)
Process temperature (thread or flange tem-
perature) with temperature adapter (option)
-50 … +250 °C (-58 … +482 °F)
26
VEGAWAVE
61 • - Relay (DPDT)
9 Supplement
32247
-EN
-120418