beautypg.com

VEGA VEGAWAVE 61 - Relay (DPDT) User Manual

Page 26

background image

Output variable

Output

Relay output (DPDT), 2 floating spdts
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.

Turn-on voltage

-

Min.

10 mV

-

Max.

253 V AC, 253 V DC
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.

Switching current

-

Min.

10 µA

-

Max.

3 A AC, 1 A DC

Breaking capacity

-

Min.

50 mW

-

Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

min./max.

Switching delay

-

When immersed

0.5 s

-

When laid bare

1 s

Ambient conditions

Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Measured variable

Limit level of solids

Process pressure

-1 … 25 bar/-100 … 2500 kPa (-14.5 … 363 psig)

VEGAWAVE

61 of 316L

-50 … +150 °C (-58 … +302 °F)

Process temperature (thread or flange tem-
perature) with temperature adapter (option)

-50 … +250 °C (-58 … +482 °F)

26

VEGAWAVE

61 • - Relay (DPDT)

9 Supplement

32247

-EN

-120418