2 mounting preparations – VEGA PLICSRADIO T61 Wireless emitting unit User Manual
Page 12
12
4 Mounting
PLICSRADIO T61 • Wireless emitting unit (single channel)
32865-EN-130322
Effective range
Mounting height 2.4 GHz Mounting height 920 MHz
500 m (1640 ft)
3.9 m (12.79 ft)
6.4 m (20.99 ft)
750 m (2460 ft)
4.8 m (15.74 ft)
7.8 m (25.59 ft)
1000 m (3280 ft)
5.6 m (18.37 ft)
9.1 m (29.85 ft)
1500 m (4921 ft)
-
11 m (36.08 ft)
Mount PLICSRADIO at the minimum height from the ground, or from
the highest obstacle that touches the Fresnel zone, as indicated in
the table; use a mast if necessary. With the 2.4 GHz standard model,
an optional external antenna with a 3 meter cable is available to allow
mounting at the required height.
Use the recommended cables (see chapter "Connecting to power
supply") and tighten the cable gland.
You can give your instrument additional protection against moisture
penetration by leading the connection cable downward in front of the
cable entry. Rain and condensation water can thus drain off. This ap-
plies mainly to outdoor mounting as well as installation in areas where
high humidity is expected (e.g. through cleaning processes) or on
cooled or heated vessels.
Fig. 5: Measures against moisture penetration
4.2 Mounting preparations
The following tools are required for mounting:
•
Allen wrench size 4
•
Phillips head size 2 or Torx size T10
•
Slotted screwdriver 3 mm
PLICSRADIO T61 in Ex version is a corresponding, intrinsically safe
piece of equipment and must not be installed in hazardous areas.
Safe operation is only ensured if the operating instructions and EG
type approval certificate are observed.
Moisture
Tools
Ex environment