beautypg.com

2 principle of operation – VEGA VEGAWAVE 63 - two-wire User Manual

Page 8

background image

l

SIL identification (with SIL rating ex works)

With the serial number, you can access the delivery data of the
instrument via www.vega.com, "VEGA Tools" and "serial number
search
". In addition to the type label outside, you can also find the
serial number on the inside of the instrument.

3

.2 Principle of operation

VEGAWAVE

63 is a point level sensor with tuning fork for level

detection.

It is designed for industrial use in all areas of process technology and
is preferably used for bulk solids.

Typical applications are overfill and dry run protection. Thanks to its
simple and robust measuring system, VEGAWAVE 63 is virtually
unaffected by the chemical and physical properties of the bulk solid.

It also works when subjected to strong external vibrations or changing
products.

Solid detection in water
If VEGAWAVE 63 was ordered for solids detection in water, the tuning
fork is set to the density of water. In air or when immersed in water
(density: 1 g/cm³/0.036 lbs/in), VEGAWAVE 63 signals "uncovered".
Only when the vibrating element is also covered with solids (e.g. sand,
sludge, gravel etc.) will the sensor signal "covered".

Fault monitoring
The electronics module of VEGAWAVE 63 monitors continuously the
following criteria:

l

Correct vibrating frequency

l

Line break to the piezo drive

If one of these faults is detected, the electronics signals this via a
defined current to the signal conditioning instrument. The connection
cable to the vibrating element is also monitored.

The tuning fork is piezoelectrically energised and vibrates at its
mechanical resonance frequency of approx. 150 Hz. When the tuning
fork is submerged in the product, the vibration amplitude changes.
This change is detected by the integrated electronics module and
converted into a switching command.

Depending on your requirements, VEGAWAVE 63 with two-wire
electronics can be connected to different signal conditioning instru-
ments. Compatible signal conditioning instruments are listed in chapter
"T

echnical data".

The data for power supply are specified in chapter "Technical data".

Application area

Functional principle

Voltage supply

8

VEGAWAVE

63 • - two-wire

3 Product description

32260

-EN

-120418