beautypg.com

VEGA VEGAKON 61 - Relay (DPDT) User Manual

Page 20

background image

surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.

Contact material (relay contacts)

AgNi or AgSnO and Au plated

Modes (adjustable)

-

A

Max. detection or overflow protection

-

B

Min. detection or dry run protection

Switching delay

-

When immersed

0.5 s

-

When laid bare

0.5 s

Ambient conditions

Ambient temperature on the housing

-40 … +70 °C (-40 … +158 °F)

Ambient temperature with operating voltage
>

60 V DC

-40 … +50 °C (-40 … +122 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Permissible process temperature

-

Without temperature adapter

-40 … +100 °C (-40 … +212 °F)

-

with temperature adapter

-40 … +150 °C (-40 … +302 °F)

1

2

110 °C

(230 °F)

120 °C

(248 °F)

100 °C

(212 °F)

130 °C

(266 °F)

140 °C

(284 °F)

150 °C

(302 °F)

50 °C

(122 °F)

60 °C

(140 °F)

70 °C

(158 °F)

Fig. 21: Ambient temperature - Process temperature

1

Process temperature in °C

2

Ambient temperature in °C

Process pressure

-1 … 25 bar/-100 … 2500 kPa (-14.5 … 362 psig)

Conductive of the medium

min. 7.5 µS/cm

20

VEGAKON

61 • - Relay (DPDT)

9 Supplement

32647

-EN

-100219